Quantification of three-dimensional facial asymmetry for diagnosis and postoperative evaluation of orthognathic surgery
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cao, Hua-Lian | - |
dc.contributor.author | Kang, Moon-Ho | - |
dc.contributor.author | Lee, Jin-Yong | - |
dc.contributor.author | Park, Won-Jong | - |
dc.contributor.author | Choung, Han-Wool | - |
dc.contributor.author | Choung, Pill-Hoon | - |
dc.date.accessioned | 2021-06-18T07:15:16Z | - |
dc.date.available | 2021-06-18T07:15:16Z | - |
dc.date.issued | 2020-05-25 | - |
dc.identifier.issn | 2288-8101 | - |
dc.identifier.issn | 2288-8586 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/44189 | - |
dc.description.abstract | Background: To evaluate the facial asymmetry, three-dimensional computed tomography (3D-CT) has been used widely. This study proposed a method to quantify facial asymmetry based on 3D-CT. Methods: The normal standard group consisted of twenty-five male subjects who had a balanced face and normal occlusion. Five anatomical landmarks were selected as reference points and ten anatomical landmarks were selected as measurement points to evaluate facial asymmetry. The formula of facial asymmetry index was designed by using the distances between the landmarks. The index value on a specific landmark indicated zero when the landmarks were located on the three-dimensional symmetric position. As the asymmetry of landmarks increased, the value of facial asymmetry index increased. For ten anatomical landmarks, the mean value of facial asymmetry index on each landmark was obtained in the normal standard group. Facial asymmetry index was applied to the patients who had undergone orthognathic surgery. Preoperative facial asymmetry and postoperative improvement were evaluated. Results: The reference facial asymmetry index on each landmark in the normal standard group was from 1.77 to 3.38. A polygonal chart was drawn to visualize the degree of asymmetry. In three patients who had undergone orthognathic surgery, it was checked that the method of facial asymmetry index showed the preoperative facial asymmetry and the postoperative improvement well. Conclusions: The current new facial asymmetry index could efficiently quantify the degree of facial asymmetry from 3D-CT. This method could be used as an evaluation standard for facial asymmetry analysis. | - |
dc.format.extent | 11 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | SPRINGER | - |
dc.title | Quantification of three-dimensional facial asymmetry for diagnosis and postoperative evaluation of orthognathic surgery | - |
dc.title.alternative | Quantification of three-dimensional facial asymmetry for diagnosis and postoperative evaluation of orthognathic surgery | - |
dc.type | Article | - |
dc.identifier.doi | 10.1186/s40902-020-00260-9 | - |
dc.identifier.bibliographicCitation | MAXILLOFACIAL PLASTIC AND RECONSTRUCTIVE SURGERY, v.42, no.1, pp 1 - 11 | - |
dc.identifier.kciid | ART002591211 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000537238800001 | - |
dc.identifier.scopusid | 2-s2.0-85099376303 | - |
dc.citation.endPage | 11 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 1 | - |
dc.citation.title | MAXILLOFACIAL PLASTIC AND RECONSTRUCTIVE SURGERY | - |
dc.citation.volume | 42 | - |
dc.type.docType | Article | - |
dc.publisher.location | 미국 | - |
dc.subject.keywordAuthor | Facial asymmetry | - |
dc.subject.keywordAuthor | Three-dimensional computed tomography | - |
dc.subject.keywordAuthor | Orthognathic surgery | - |
dc.subject.keywordPlus | 3D-CT EVALUATION | - |
dc.subject.keywordPlus | IMAGE-ANALYSIS | - |
dc.subject.keywordPlus | CEPHALOMETRY | - |
dc.subject.keywordPlus | ERRORS | - |
dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |
dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
dc.description.journalRegisteredClass | esci | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.