Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Reliability and Validity of Attitude and Heading Reference System Motion Estimation in a Novel Mirror Therapy System

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Wonshik-
dc.contributor.authorBeom, Jaewon-
dc.contributor.authorPark, Chulwoo-
dc.contributor.authorKoh, Sukgyu-
dc.contributor.authorKim, Yoon Jae-
dc.contributor.authorKim, Youdan-
dc.contributor.authorChung, Sun Gun-
dc.contributor.authorKim, Sungwan-
dc.date.accessioned2021-06-18T07:42:29Z-
dc.date.available2021-06-18T07:42:29Z-
dc.date.issued2018-06-
dc.identifier.issn1609-0985-
dc.identifier.issn2199-4757-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/45257-
dc.description.abstractIn this study, we conducted an experiment for validating a motion estimation system used in novel mirror therapy. The proposed motion estimation system consists of two parts. The first part is motion estimation using attitude and heading reference system sensors. The system attaches a reference frame to a patient to provide flexibility to the patient's movements. The second part is a compensation algorithm that uses principal component analysis (PCA). Ten subjects performed simple reaching tasks for the validation experiment. The results showed success rate of 89.67% under normal conditions. The PCA-based compensation algorithm increases the success rate from 89.67 to 92.89%. Accurate capturing of healthy arm motion will make effective robot-aided mirror therapy systems feasible.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherSPRINGER HEIDELBERG-
dc.titleReliability and Validity of Attitude and Heading Reference System Motion Estimation in a Novel Mirror Therapy System-
dc.typeArticle-
dc.identifier.doi10.1007/s40846-017-0315-4-
dc.identifier.bibliographicCitationJOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, v.38, no.3, pp 370 - 377-
dc.description.isOpenAccessN-
dc.identifier.wosid000432631500004-
dc.identifier.scopusid2-s2.0-85047355258-
dc.citation.endPage377-
dc.citation.number3-
dc.citation.startPage370-
dc.citation.titleJOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING-
dc.citation.volume38-
dc.type.docTypeArticle-
dc.publisher.location대만-
dc.subject.keywordAuthorAttitude and heading reference system-
dc.subject.keywordAuthorInertia measurement unit-
dc.subject.keywordAuthorMotion estimation-
dc.subject.keywordAuthorRobot-aided mirror therapy-
dc.subject.keywordAuthorPrincipal component analysis-
dc.subject.keywordAuthorRobotic rehabilitation-
dc.subject.keywordPlusMOTOR FUNCTION-
dc.subject.keywordPlusSTROKE-
dc.subject.keywordPlusREHABILITATION-
dc.subject.keywordPlusORIENTATION-
dc.subject.keywordPlusMOVEMENT-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE