Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fibronectin-Grafted Titanium Dental Implants: An In Vivo Study

Full metadata record
DC Field Value Language
dc.contributor.authorChang, Yu-Chi-
dc.contributor.authorHo, Kuo-Ning-
dc.contributor.authorFeng, Sheng-Wei-
dc.contributor.authorHuang, Haw-Ming-
dc.contributor.authorChang, Chia-Hsun-
dc.contributor.authorLin, Che-Tong-
dc.contributor.authorTeng, Nai-Chia-
dc.contributor.authorPan, Yu Hwa-
dc.contributor.authorChang, Wei-Jen-
dc.date.accessioned2021-06-18T09:40:48Z-
dc.date.available2021-06-18T09:40:48Z-
dc.date.issued2016-
dc.identifier.issn2314-6133-
dc.identifier.issn2314-6141-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/45713-
dc.description.abstractModification of the physiochemical properties of titanium surfaces using glow discharge plasma (GDP) and fibronectin coating has been shown to enhance the surface hydrophilicity, surface roughness, cell adhesion, migration, and proliferation. This in vivo study aimed to evaluate the bone integration efficacy of a biologically modified implant surface. Two different surface-modified implants (Ar-GDP and GDP-fib) were placed in the mandibular premolar area of six beagle dogs for 2-8 weeks. Three techniques [ histologic evaluation, resonance frequency analysis (RFA), and microcomputed tomography (micro-CT) evaluation] were used to detect the implant stability and bone-implant contact. The implant stability quotient values of GDP-fib implantswere significantly greater than the Ar-GDP implants at 2 and 4 weeks (P < 0.01). The bone volume/total volume ratio of GDP-fib implants was greater than the Ar-GDP implants in micro-CT evaluation. A high positive correlation was observed between RFA and micro-CT measurements. At 2 weeks, osteoblasts were seen to line the implant surface, and multinuclear osteoclasts could be seen on the surface of old parent bone. After 8 weeks, a majority of the space in the wound chamber appeared to be replaced by bone. Enhancement of the stability of biologically modified implants was proved by the results of RFA, micro-CT, and histological analysis. This enhanced stability may help fasten treatment and be clinically beneficial.-
dc.language영어-
dc.language.isoENG-
dc.publisherHINDAWI LTD-
dc.titleFibronectin-Grafted Titanium Dental Implants: An In Vivo Study-
dc.typeArticle-
dc.identifier.doi10.1155/2016/2414809-
dc.identifier.bibliographicCitationBIOMED RESEARCH INTERNATIONAL, v.2016-
dc.description.isOpenAccessY-
dc.identifier.wosid000378283800001-
dc.identifier.scopusid2-s2.0-84976412915-
dc.citation.titleBIOMED RESEARCH INTERNATIONAL-
dc.citation.volume2016-
dc.type.docTypeArticle-
dc.publisher.location미국-
dc.subject.keywordPlusGLOW-DISCHARGE PLASMA-
dc.subject.keywordPlusRESONANCE FREQUENCY-ANALYSIS-
dc.subject.keywordPlusBONE-FORMATION ADJACENT-
dc.subject.keywordPlusACID-ETCHED SURFACE-
dc.subject.keywordPlusHISTOMORPHOMETRIC EVALUATION-
dc.subject.keywordPlusALVEOLAR BONE-
dc.subject.keywordPlusOSSEOINTEGRATION-
dc.subject.keywordPlusSTABILITY-
dc.subject.keywordPlusCELLS-
dc.subject.keywordPlusIMMEDIATE-
dc.relation.journalResearchAreaBiotechnology & Applied Microbiology-
dc.relation.journalResearchAreaResearch & Experimental Medicine-
dc.relation.journalWebOfScienceCategoryBiotechnology & Applied Microbiology-
dc.relation.journalWebOfScienceCategoryMedicine, Research & Experimental-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE