A portable surface-enhanced Raman scattering sensor integrated with a lab-on-a-chip for field analysis
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Quang, Ly Xuan | - |
dc.contributor.author | Lim, Chaesung | - |
dc.contributor.author | Seong, Gi Hun | - |
dc.contributor.author | Choo, Jaebum | - |
dc.contributor.author | Do, Ki Jun | - |
dc.contributor.author | Yoo, Seoung-Kyo | - |
dc.date.accessioned | 2021-06-18T13:41:19Z | - |
dc.date.available | 2021-06-18T13:41:19Z | - |
dc.date.issued | 2008-12 | - |
dc.identifier.issn | 1473-0197 | - |
dc.identifier.issn | 1473-0189 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/46944 | - |
dc.description.abstract | An integrated real-time sensing system that uses a portable Raman spectrometer and a micropillar array chip has been developed for field analysis. The problem of poor detection sensitivity, caused by miniaturization in the portable Raman spectrometer, was overcome by using the surface-enhanced Raman scattering (SERS) technique. The problem of poor reproducibility in the SERS detection, caused by different particle sizes and inhomogeneous degrees of aggregation, was also overcome by using continuous flow and homogeneous mixing between the analytes and nanocolloidal silver in a micropillar array microfluidic chip. Two hazardous materials, dipicolinic acid and malachite green, were quantitatively analysed using our integrated portable Raman sensor system. The observed limit of detection was estimated to be 200 ppb and 500 ppb, respectively. Our proposed analytical method, using a micropillar array PDMS chip and a portable SERS system, offers a rapid and reproducible trace detection capability for hazardous materials in the field. | - |
dc.format.extent | 6 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | ROYAL SOC CHEMISTRY | - |
dc.title | A portable surface-enhanced Raman scattering sensor integrated with a lab-on-a-chip for field analysis | - |
dc.type | Article | - |
dc.identifier.doi | 10.1039/b808835g | - |
dc.identifier.bibliographicCitation | LAB ON A CHIP, v.8, no.12, pp 2214 - 2219 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000261686200031 | - |
dc.identifier.scopusid | 2-s2.0-56549088127 | - |
dc.citation.endPage | 2219 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | 2214 | - |
dc.citation.title | LAB ON A CHIP | - |
dc.citation.volume | 8 | - |
dc.type.docType | Article | - |
dc.publisher.location | 영국 | - |
dc.subject.keywordPlus | BACILLUS-SUBTILIS ENDOSPORE | - |
dc.subject.keywordPlus | SENSITIVE TRACE ANALYSIS | - |
dc.subject.keywordPlus | MALACHITE GREEN | - |
dc.subject.keywordPlus | MICROFLUIDIC SYSTEM | - |
dc.subject.keywordPlus | SELECTIVE DETECTION | - |
dc.subject.keywordPlus | SPECTROSCOPY | - |
dc.subject.keywordPlus | DNA | - |
dc.subject.keywordPlus | SILVER | - |
dc.subject.keywordPlus | SPECTROMETRY | - |
dc.subject.keywordPlus | SERRS | - |
dc.relation.journalResearchArea | Biochemistry & Molecular Biology | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Biochemical Research Methods | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Nanoscience & Nanotechnology | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.