Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Simultaneous determination of five porphyrins in human urine and plasma using high performance liquid chromatography-tandem mass spectrometry

Authors
Hur, Y.Tae, S.Koh, Y.-J.Hong, S.-H.Yoon, Y.H.Jang, H.Kim, S.Kim, K.H.Kang, S.W.Lee, Y.Han, S.B.
Issue Date
2014
Publisher
Korean Society for Mass Spectrometry
Keywords
Autism; Diagnosis; Plasma; Porphyrins; Tandem mass spectrometry; Urine
Citation
Mass Spectrometry Letters, v.5, no.2, pp 42 - 48
Pages
7
Journal Title
Mass Spectrometry Letters
Volume
5
Number
2
Start Page
42
End Page
48
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/48837
DOI
10.5478/MSL.2014.5.2.42
ISSN
2233-4203
2093-8950
Abstract
A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESIMS/ MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column (150 mm × 2.0 mm, 4 μm) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/ v) at a flow rate of 450 μL/min. Porphyrins and the internal standard (IS), coproporphyrin I-15N4, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Pharmacy > School of Pharmacy > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang Beom photo

Han, Sang Beom
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE