Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity

Full metadata record
DC Field Value Language
dc.contributor.authorYoon, Jeong Hee-
dc.contributor.authorLee, Jeong Min-
dc.contributor.authorLee, Eun Sun-
dc.contributor.authorBaek, Jeehyun-
dc.contributor.authorLee, Sangwoo-
dc.contributor.authorIwadate, Yuji-
dc.contributor.authorHan, Joon Koo-
dc.contributor.authorChoi, Byung Ihn-
dc.date.accessioned2021-09-14T07:40:38Z-
dc.date.available2021-09-14T07:40:38Z-
dc.date.issued2015-02-
dc.identifier.issn0942-8925-
dc.identifier.issn1432-0509-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/49126-
dc.description.abstractPurpose: To determine whether a navigator-gated three-dimensional T1-weighted gradient-echo sequence (T1W-GRE, navigated LAVA) can improve diagnostic performance for the detection of focal liver lesions (FLLs) compared to standard breath-hold (BH) T1W-GRE breath-hold LAVA (BH-LAVA) during the hepatobiliary phase (HBP) of gadoxetic acid liver magnetic resonance imaging (MRI) in patients with limited breath-holding capacity. Materials and methods: This retrospective study was approved by our institutional review board and the requirement for informed consent was waived. We included 372 patients who underwent liver MRI including both navigated LAVA and BH-LAVA sequences. Overall image quality of the two HBP image sets was compared. In patients with limited breath-holding capacity, diagnostic performances in detecting FLLs on the two HBP images were compared using jackknife-alternative free-response receiver-operating characteristic (JAFROC) analysis by two reviewers. Results: There were 13 cases (13/372; 3.5%) of image acquisition failure using the navigated LAVA sequence due to severe irregular breathing, and 50 of 359 patients had limited breath-holding capacity. In these patients, overall image quality of navigated LAVA (2.78 +/- 0.95) was significantly better than that of BH-LAVA (2.42 +/- 0.81, P < 0.005), and both readers showed significantly higher JAFROC figure-of-merit values with navigated LAVA compared to BH-LAVA (0.94 and 0.86 in reviewer 1, respectively; 0.89 and 0.83 in reviewer 2, respectively, P < 0.005). Overall image quality of navigated LAVA was also better than that of BH-LAVA in patients with sufficient breath-holding capacity (n = 309, 3.96 +/- 0.88, 3.81 +/- 0.66, respectively, P < 0.001). Conclusion: The navigated LAVA sequence could provide better image quality and diagnostic performance in detecting FLLs than BH-LAVA in patients with limited breath-holding capacity during HBP of gadoxetic acid MRI.-
dc.format.extent11-
dc.language영어-
dc.language.isoENG-
dc.publisherSPRINGER-
dc.titleNavigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity-
dc.typeArticle-
dc.identifier.doi10.1007/s00261-014-0214-x-
dc.identifier.bibliographicCitationABDOMINAL IMAGING, v.40, no.2, pp 278 - 288-
dc.description.isOpenAccessN-
dc.identifier.wosid000348298800008-
dc.citation.endPage288-
dc.citation.number2-
dc.citation.startPage278-
dc.citation.titleABDOMINAL IMAGING-
dc.citation.volume40-
dc.type.docTypeArticle-
dc.publisher.location미국-
dc.subject.keywordAuthorMagnetic resonance imaging-
dc.subject.keywordAuthorHepatobiliary phase-
dc.subject.keywordAuthorRespiratory-gated imaging-
dc.subject.keywordAuthorGd-EOB-DTPA-
dc.subject.keywordAuthorGadoxetic acid-
dc.subject.keywordPlusHEPATOCELLULAR CARCINOMAS-
dc.subject.keywordPlusOBSERVER PERFORMANCE-
dc.subject.keywordPlusHEPATOBILIARY-PHASE-
dc.subject.keywordPlusHEPATOCYTE PHASE-
dc.subject.keywordPlusFLIP ANGLE-
dc.subject.keywordPlusEOB-DTPA-
dc.subject.keywordPlus3.0 T-
dc.subject.keywordPlusMRI-
dc.subject.keywordPlusMETASTASES-
dc.subject.keywordPlusNODULES-
dc.relation.journalResearchAreaGastroenterology & Hepatology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryGastroenterology & Hepatology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Eun Sun photo

Lee, Eun Sun
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE