Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Anterior Bridging Bone in a Newly Designed Cage for Lumbar Interbody Fusion: Radiographic and Finite Element Analysis

Authors
Lee, J.Chang, S.-H.Cho, H.-C.Song, K.-S.
Issue Date
Oct-2021
Publisher
Elsevier Inc.
Keywords
Bridging bone; Cage; Computed tomography; Finite element analysis; Interbody fusion; Spine
Citation
World Neurosurgery, v.154, pp E389 - E397
Journal Title
World Neurosurgery
Volume
154
Start Page
E389
End Page
E397
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/49584
DOI
10.1016/j.wneu.2021.07.044
ISSN
1878-8750
1878-8769
Abstract
Objective: To evaluate the distribution of multiple anterior bridging bone (ABB) patterns using a newly designed interbody cage with 4 anterior holes that enable communication between the inside and outside of the cage and to estimate its mechanical effect by finite element analysis (FEA). Methods: Patients underwent single-level lumbar interbody fusion using ABB cages. Two raters evaluated the distribution patterns of ABB on computed tomography scans 1 year after surgery. We defined the term H-fusion as the presence of complete anterior extracage and intracage bone bridging, with ≥1 ABBs between them. We performed finite element analysis to investigate the effect of ABB on maximal stiffness. Results: The study enrolled 98 patients. ABB was most frequently observed in the medial hole of the cages (73.7%). The mean number of ABBs was 3.65, and H-fusion was observed at 135 levels (34%). Postoperative improvement in the Oswestry Disability Index was significantly higher in patients who achieved interbody fusion and H-fusion than in patients who did not. As ABB was added, the increment in the relative maximal stiffness was most affected under flexion and extension forces. Conclusions: We observed an average of 3.65 complete ABBs. Finite element analysis demonstrated that ABB could increase the stability in fused segments, especially under flexion and extension stress. Our results suggest that the ABB cage, which allows communicating cross-bridging between inside and outside of the cage, may facilitate a more stable fusion process than a conventionally designed cage. © 2021 Elsevier Inc.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Kwang Sup photo

Song, Kwang Sup
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE