Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Abdominal Digital Radiography with a Novel Post-Processing Technique: Phantom and Patient Studies

Full metadata record
DC Field Value Language
dc.contributor.author강혜인-
dc.contributor.author이은선-
dc.contributor.author박현정-
dc.contributor.author박병관-
dc.contributor.author박재용-
dc.contributor.author서석원-
dc.date.accessioned2021-11-15T06:41:16Z-
dc.date.available2021-11-15T06:41:16Z-
dc.date.issued2020-07-
dc.identifier.issn1738-2637-
dc.identifier.issn2288-2928-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/51386-
dc.description.abstractPurpose The aim of this study was to evaluate the diagnostic image quality of low dose abdominal digital radiography processed with a new post-processing technique. Materials and Methods Abdominal radiographs from phantom pilot studies were post-processed by the novel and conventional post-processing methods of our institution; the proper dose for the subsequent patient study of 49 subjects was determined by comparing image quality of the two preceding studies. Two radiographs of each patient were taken using the conventional and derived dose protocols with the proposed post-processing method. The image details and quality were evaluated by two radiologists. Results The radiation dose for the patient study was derived to be half of the conventional method. Overall half-dose image quality with the proposed method was significantly higher than that of the conventional method (p < 0.05) with moderate inter-rater agreement (κ = 0.60, 0.47). Conclusion By applying the new post-processing technique, half-dose abdominal digital radiography can demonstrate feasible image quality compared to the full-dose images.-
dc.format.extent13-
dc.language영어-
dc.language.isoENG-
dc.publisher대한영상의학회-
dc.titleAbdominal Digital Radiography with a Novel Post-Processing Technique: Phantom and Patient Studies-
dc.title.alternative새로운 후처리 기술을 이용한 복부 디지털 방사선 촬영: 팬텀과 환자 연구-
dc.typeArticle-
dc.identifier.doi10.3348/jksr.2020.81.4.920-
dc.identifier.bibliographicCitation대한영상의학회지, v.81, no.4, pp 920 - 932-
dc.identifier.kciidART002612176-
dc.description.isOpenAccessY-
dc.identifier.scopusid2-s2.0-85091696932-
dc.citation.endPage932-
dc.citation.number4-
dc.citation.startPage920-
dc.citation.title대한영상의학회지-
dc.citation.volume81-
dc.publisher.location대한민국-
dc.subject.keywordAuthorRadiography-
dc.subject.keywordAuthorAbdominal-
dc.subject.keywordAuthorRadiography-
dc.subject.keywordAuthorImage Enhancement-
dc.subject.keywordAuthorComparative Study-
dc.subject.keywordAuthorRadiation Dosage-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Byung Kwan photo

Park, Byung Kwan
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE