dc.description.abstract | Objective: This study aimed to verify the effect of introducing a feedback device during adult and infant cardiopulmonary resuscitation training. Methods: A feedback device was introduced in the cardiopulmonary resuscitation training course of our medical school in the middle of the last semester. The cardiopulmonary resuscitation training course consisted of 2 h of instructor-led cardiopulmonary resuscitation training and 1 h of self-practice time. All students should complete the adult and infant cardiopulmonary resuscitation skill tests just after the course. Each test consisted of five cycles of single-rescuer cardiopulmonary resuscitation. A feedback device was introduced only in the self-practice session. The cardiopulmonary resuscitation parameters of the skill tests before (n = 40) and after (n = 39) introducing the feedback device were analysed. Results: The ratios of correct rate significantly increased after introducing the feedback device in both the skill tests (adult test: 58.5 ± 37.2 vs 85.5 ± 21.4, p = 0.001; infant test: 55.0 ± 32.4 vs 80.2 ± 20.7, p = 0.001). Although the average depths did not significantly differ between those before and after introducing the feedback device in the adult test (58.4 ± 4.0 mm vs 59.0 ± 3.7 mm, p = 0.341), it increased significantly after introducing the feedback device in the infant test (38.3 ± 4.3 mm vs 40.8 ± 1.1 mm, p = 0.001). Conclusion: Introducing a feedback device might have enhanced the accuracies of compression rate in adult and infant cardiopulmonary resuscitation training. However, the potential positive effect on chest compression depth was limited to infant cardiopulmonary resuscitation training. © The Author(s) 2018. | - |
dc.format.extent | 4 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | SAGE Publications Ltd | - |
dc.title | Effect of introducing a feedback device during adult and infant cardiopulmonary resuscitation training: A ‘before and after’ study | - |
dc.type | Article | - |
dc.identifier.doi | 10.1177/1024907918801488 | - |
dc.identifier.bibliographicCitation | Hong Kong Journal of Emergency Medicine, v.27, no.2, pp 114 - 117 | - |
dc.description.isOpenAccess | Y | - |
dc.identifier.wosid | 000517492400010 | - |
dc.identifier.scopusid | 2-s2.0-85058848231 | - |
dc.citation.endPage | 117 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 114 | - |
dc.citation.title | Hong Kong Journal of Emergency Medicine | - |
dc.citation.volume | 27 | - |
dc.type.docType | Article in Press | - |
dc.publisher.location | 중국 | - |
dc.subject.keywordAuthor | adult | - |
dc.subject.keywordAuthor | Cardiopulmonary resuscitation | - |
dc.subject.keywordAuthor | feedback | - |
dc.subject.keywordAuthor | infant | - |
dc.subject.keywordAuthor | training | - |
dc.subject.keywordPlus | adult | - |
dc.subject.keywordPlus | article | - |
dc.subject.keywordPlus | clinical article | - |
dc.subject.keywordPlus | controlled study | - |
dc.subject.keywordPlus | female | - |
dc.subject.keywordPlus | human | - |
dc.subject.keywordPlus | infant | - |
dc.subject.keywordPlus | male | - |
dc.subject.keywordPlus | medical school | - |
dc.subject.keywordPlus | resuscitation | - |
dc.subject.keywordPlus | skill | - |
dc.subject.keywordPlus | student | - |
dc.subject.keywordPlus | training | - |
dc.relation.journalResearchArea | Emergency Medicine | - |
dc.relation.journalWebOfScienceCategory | Emergency Medicine | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.