Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Compton-edge-based energy calibration of double-sided silicon strip detectors in Compton camera

Full metadata record
DC Field Value Language
dc.contributor.authorSeo, Hee-
dc.contributor.authorPark, Jin Hyung-
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorLee, Ju Hahn-
dc.contributor.authorLee, Chun Sik-
dc.contributor.authorLee, Jae Sung-
dc.date.accessioned2022-01-06T04:41:15Z-
dc.date.available2022-01-06T04:41:15Z-
dc.date.issued2011-05-
dc.identifier.issn0168-9002-
dc.identifier.issn1872-9576-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/52969-
dc.description.abstractAccurate energy calibration of double-sided silicon strip detectors (DSSDs) is very important, but challenging for high-energy photons. In the present study, the calibration was improved by considering the Compton edge additionally to the existing low-energy calibration points. The result, indeed, was very encouraging. The energy-calibration errors were dramatically reduced, from, on average, 15.5% and 16.9% to 0.47% and 0.31% for the 356 ((133)Ba) and 662 keV ((137)Cs) peaks, respectively. The imaging resolution of a double-scattering-type Compton camera using DSSDs as the scatterer detectors, for a (22)Na point-like source, also was improved, by similar to 9%. (c) 2010 Elsevier B.V. All rights reserved.-
dc.language영어-
dc.language.isoENG-
dc.publisherELSEVIER SCIENCE BV-
dc.titleCompton-edge-based energy calibration of double-sided silicon strip detectors in Compton camera-
dc.typeArticle-
dc.identifier.doi10.1016/j.nima.2010.06.138-
dc.identifier.bibliographicCitationNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.633, no.SUPPL. 1, pp S108 - S110-
dc.description.isOpenAccessN-
dc.identifier.wosid000292782400033-
dc.identifier.scopusid2-s2.0-79959829748-
dc.citation.endPageS110-
dc.citation.numberSUPPL. 1-
dc.citation.startPageS108-
dc.citation.titleNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT-
dc.citation.volume633-
dc.type.docTypeArticle; Proceedings Paper-
dc.publisher.location네델란드-
dc.subject.keywordAuthorEnergy calibration-
dc.subject.keywordAuthorCompton edge-
dc.subject.keywordAuthorDSSD-
dc.subject.keywordAuthorCompton camera-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryPhysics, Nuclear-
dc.relation.journalWebOfScienceCategoryPhysics, Particles & Fields-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Sciences > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE