Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effect of detector parameters on the image quality of Compton camera for Tc-99m

Full metadata record
DC Field Value Language
dc.contributor.authorAn, S. H.-
dc.contributor.authorSeo, H.-
dc.contributor.authorLee, J. H.-
dc.contributor.authorLee, C. S.-
dc.contributor.authorLee, J. S.-
dc.contributor.authorKim, C. H.-
dc.date.accessioned2022-01-11T05:43:27Z-
dc.date.available2022-01-11T05:43:27Z-
dc.date.issued2007-02-
dc.identifier.issn0168-9002-
dc.identifier.issn1872-9576-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/53289-
dc.description.abstractThe Compton camera has a bright future as a medical imaging device considering its compactness, low patient dose, multiple-radioisotope tracing capability, inherent three dimensional (3D) imaging capability at a fixed position, etc. Currently, however, the image resolution of the Compton camera is not sufficient for medical imaging. In this study, we investigated the influence of various detector parameters on the image quality of the Compton camera for Tc-99m with GEANT4. Our result shows that the segmentation of the detectors significantly affects the image resolution of the Compton camera. The energy discrimination of the detectors was found to significantly affect both the sensitivity and spatial resolution. The use of a higher energy gamma source (e.g., F-18 emitting 511 keV photons), however, will significantly improve the spatial resolution of the Compton camera. It will also minimize the effect of the detector energy resolution. (c) 2006 Elsevier B.V. All rights reserved.-
dc.format.extent4-
dc.language영어-
dc.language.isoENG-
dc.publisherELSEVIER SCIENCE BV-
dc.titleEffect of detector parameters on the image quality of Compton camera for Tc-99m-
dc.typeArticle-
dc.identifier.doi10.1016/j.nima.2006.10.075-
dc.identifier.bibliographicCitationNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.571, no.1-2, pp 251 - 254-
dc.description.isOpenAccessN-
dc.identifier.wosid000244599100060-
dc.identifier.scopusid2-s2.0-33846360977-
dc.citation.endPage254-
dc.citation.number1-2-
dc.citation.startPage251-
dc.citation.titleNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT-
dc.citation.volume571-
dc.type.docTypeArticle; Proceedings Paper-
dc.publisher.location네델란드-
dc.subject.keywordAuthorCompton camera-
dc.subject.keywordAuthormedical imaging-
dc.subject.keywordAuthordetector simulation-
dc.subject.keywordAuthorMonte Carlo-
dc.subject.keywordAuthorGEANT4-
dc.subject.keywordAuthorimage resolution-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryPhysics, Nuclear-
dc.relation.journalWebOfScienceCategoryPhysics, Particles & Fields-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Sciences > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE