Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

연속 스캐닝 레이저 진동계 신호의 Hilnert 변환을 이용한 실험적 모드 해석

Full metadata record
DC Field Value Language
dc.contributor.author강민식-
dc.contributor.author장태규-
dc.contributor.author김호성-
dc.date.accessioned2022-04-11T10:40:36Z-
dc.date.available2022-04-11T10:40:36Z-
dc.date.issued2002-06-
dc.identifier.issn1229-6287-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/56222-
dc.description.abstract- This paper deals with the vibration deflection shape measurement technique for a sinusoidally excited structure using a continuously scanning laser Doppler vibrometer (CSLV). The CSLV output signal is an amplitude-modulated vibration in which the excitation signal is modulated by the deflection shapes, and thus the deflection shapes of vibration defined along a scan line can be derived by the envelop and the phase information of the CSLV output signal. In this work, a Hilbert transform based approach has been proposed for measurement of deflection shapes. This technique is as simple as the demodulation technique and allows more convenient experimental settings than the Fourier transform approach. The feasibility of the proposed technique is illustrated along with results of experiment.-
dc.format.extent7-
dc.publisher대한전기학회-
dc.title연속 스캐닝 레이저 진동계 신호의 Hilnert 변환을 이용한 실험적 모드 해석-
dc.title.alternativeExperimental Modal Analysis by Using Hilbert Transform of Signal From Continuous Scanning Laser Vibrometer-
dc.typeArticle-
dc.identifier.bibliographicCitation전기학회논문지 D권, v.51, no.6, pp 272 - 278-
dc.identifier.kciidART000905446-
dc.description.isOpenAccessN-
dc.citation.endPage278-
dc.citation.number6-
dc.citation.startPage272-
dc.citation.title전기학회논문지 D권-
dc.citation.volume51-
dc.publisher.location대한민국-
dc.subject.keywordAuthorCSLV-
dc.subject.keywordAuthorvibration mode-
dc.subject.keywordAuthorHilbert transform-
dc.subject.keywordAuthor복조-
dc.subject.keywordAuthorFourier transform-
dc.subject.keywordAuthorCSLV-
dc.subject.keywordAuthorvibration mode-
dc.subject.keywordAuthorHilbert transform-
dc.subject.keywordAuthor복조-
dc.subject.keywordAuthorFourier transform-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of ICT Engineering > School of Electrical and Electronics Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE