Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial. for Comparison with Conventional. CT Urography
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Sang Youn | - |
dc.contributor.author | Cho, Jeong Yeon | - |
dc.contributor.author | Lee, Joongyub | - |
dc.contributor.author | Hwang, Sung Il | - |
dc.contributor.author | Moon, Min Hoan | - |
dc.contributor.author | Lee, Eun Ju | - |
dc.contributor.author | Hong, Seong Sook | - |
dc.contributor.author | Kim, Chan Kyo | - |
dc.contributor.author | Kim, Kyeong Ah | - |
dc.contributor.author | Park, Sung Bin | - |
dc.contributor.author | Sung, Deuk Jae | - |
dc.contributor.author | Kim, Yongsoo | - |
dc.contributor.author | Kim, You Me | - |
dc.contributor.author | Jung, Sung Il | - |
dc.contributor.author | Rha, Sung Eun | - |
dc.contributor.author | Kim, Dong Won | - |
dc.contributor.author | Lee, Hyun | - |
dc.contributor.author | Shim, Youngsup | - |
dc.contributor.author | Hwang, Inpyeong | - |
dc.contributor.author | Woo, Sungmin | - |
dc.contributor.author | Choi, Hyuck Jae | - |
dc.date.available | 2019-01-22T12:29:45Z | - |
dc.date.issued | 2018-11 | - |
dc.identifier.issn | 1229-6929 | - |
dc.identifier.issn | 2005-8330 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/593 | - |
dc.description.abstract | Objective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose (5.73 +/- 4.04 vs. 8.43 +/- 4.38 mSv) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score >= 3), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced. | - |
dc.format.extent | 11 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | KOREAN RADIOLOGICAL SOC | - |
dc.title | Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial. for Comparison with Conventional. CT Urography | - |
dc.type | Article | - |
dc.identifier.doi | 10.3348/kjr.2018.19.6.1119 | - |
dc.identifier.bibliographicCitation | KOREAN JOURNAL OF RADIOLOGY, v.19, no.6, pp 1119 - 1129 | - |
dc.identifier.kciid | ART002409790 | - |
dc.description.isOpenAccess | Y | - |
dc.identifier.wosid | 000447774500011 | - |
dc.identifier.scopusid | 2-s2.0-85055591641 | - |
dc.citation.endPage | 1129 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 1119 | - |
dc.citation.title | KOREAN JOURNAL OF RADIOLOGY | - |
dc.citation.volume | 19 | - |
dc.type.docType | Article | - |
dc.publisher.location | 대한민국 | - |
dc.subject.keywordAuthor | Computed tomography | - |
dc.subject.keywordAuthor | Low dose | - |
dc.subject.keywordAuthor | Urography | - |
dc.subject.keywordAuthor | Contrast media | - |
dc.subject.keywordAuthor | Double dose reduction | - |
dc.subject.keywordPlus | FILTERED BACK-PROJECTION | - |
dc.subject.keywordPlus | RADIATION-DOSE REDUCTION | - |
dc.subject.keywordPlus | 256-DETECTOR ROW CT | - |
dc.subject.keywordPlus | IMAGE QUALITY | - |
dc.subject.keywordPlus | COMPUTED-TOMOGRAPHY | - |
dc.subject.keywordPlus | URINARY-TRACT | - |
dc.subject.keywordPlus | ABDOMINAL CT | - |
dc.subject.keywordPlus | MULTIDETECTOR CT | - |
dc.subject.keywordPlus | DYNAMIC CT | - |
dc.subject.keywordPlus | OPTIMIZATION | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.