Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Biomimetic isolation of affinity peptides for electrochemical detection of influenza virus antigen

Authors
Kim, Ji HongCho, Chae HwanShin, Jae HwanHyun, Moon SeopHwang, EunhaPark, Tae JungPark, Jong Pil
Issue Date
Sep-2021
Publisher
Elsevier B.V.
Keywords
Affinity peptide; Hemagglutinin; Influenza virus; Molecular receptor; Peptide sensor
Citation
Sensors and Actuators, B: Chemical, v.343
Journal Title
Sensors and Actuators, B: Chemical
Volume
343
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/62217
DOI
10.1016/j.snb.2021.130161
ISSN
0925-4005
0925-4005
Abstract
In this study, we developed an electrochemical biosensor coated with a peptide that can detect the protein hemagglutinin (HA) present in the envelope of the influenza virus (H5N1). Using phage display, high-affinity peptide-displaying phage particles (GHPHYNNPSLQL) with specific binding abilities for HA were identified, which were evaluated using enzyme-linked immunosorbent assays (ELISAs). Based on the molecular structure identified by the functional studies, six newly designed peptides were chemically synthesized, and their binding interactions with HA proteins were characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM), isothermal titration calorimetry (ITC), and surface plasmon resonance spectroscopy (SPR). Square wave voltammetry (SWV) revealed the presence of a linear relationship between the change in current and concentration of HA protein. From these observations, we selected IFA BP1 peptide as a potential molecular receptor and confirmed that the limit of detection (LOD) was found to be 3.26 nM. In addition, our electrochemical sensor successfully detected HA spiked in human plasma samples. Furthermore, good results for reproducibility and recovery using this biosensor were observed within a range of 31.2–500 nM concentrations and 82.3–111.5%, respectively. Importantly, the levels of HA proteins in the samples of human plasma measured using this sensor system corresponded well with those determined using a commercial ELISA method and also offered advantages such as low cost of fabrication, faster analysis, and use of lower sample volumes, suggesting that it could be applied for rapid and effective detection of the influenza virus antigen. © 2021 Elsevier B.V.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Sciences > Department of Chemistry > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jong Pil photo

Park, Jong Pil
대학원 (식품생명공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE