Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Assessment of reliability and validity of the 5-scale grading system of the point-of-care immunoassay for tear matrix metalloproteinase-9

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Minjeong-
dc.contributor.authorOh, Ja Young-
dc.contributor.authorBae, Seon Ha-
dc.contributor.authorLee, Seung Hyeun-
dc.contributor.authorLee, Won Jun-
dc.contributor.authorChun, Yeoun Sook-
dc.contributor.authorKim, Kyoung Woo-
dc.date.accessioned2023-03-08T10:55:50Z-
dc.date.available2023-03-08T10:55:50Z-
dc.date.issued2021-06-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/62410-
dc.description.abstractWe evaluated the reliability and validity of the 5-scale grading system to interpret the point-of-care immunoassay for tear matrix metalloproteinase (MMP)-9. Six observers graded red bands of photographs of the readout window in MMP-9 immunoassay kit (InflammaDry) two times with 2-week interval based on the 5-scale grading system (i.e. grade 0–4). Interobserver and intraobserver reliability were evaluated using intraclass correlation coefficients. The interobserver agreements were analyzed according to the severity of tear MMP-9 expression. To validate the system, a concentration calibration curve was made using MMP-9 solutions with reference concentrations, then the distribution of MMP-9 concentrations was analyzed according to the 5-scale grading system. Both intraobserver and interobserver reliability was excellent. The readout grades were significantly correlated with the quantified colorimetric densities. The interobserver variance of readout grades had no correlation with the severity of the measured densities. The band density continued to increase up to a maximal concentration (i.e. 5000 ng/mL) according to the calibration curve. The difference of grades reflected the change of MMP-9 concentrations sensitively, especially between grade 2 and 4. Together, our data indicate that the subjective 5-scale grading system in the point-of-care MMP-9 immunoassay is an easy and reliable method with acceptable accuracy. © 2021, The Author(s).-
dc.language영어-
dc.language.isoENG-
dc.publisherNature Research-
dc.titleAssessment of reliability and validity of the 5-scale grading system of the point-of-care immunoassay for tear matrix metalloproteinase-9-
dc.typeArticle-
dc.identifier.doi10.1038/s41598-021-92020-6-
dc.identifier.bibliographicCitationScientific Reports, v.11, no.1-
dc.description.isOpenAccessN-
dc.identifier.wosid000663778500015-
dc.identifier.scopusid2-s2.0-85107693835-
dc.citation.number1-
dc.citation.titleScientific Reports-
dc.citation.volume11-
dc.type.docTypeArticle-
dc.publisher.location영국-
dc.subject.keywordPlusDRY-
dc.subject.keywordPlusSENSOR-
dc.subject.keywordPlusMMP-9-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chun, Yeoun Sook photo

Chun, Yeoun Sook
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE