Evaluation of Human Body Characteristics for Electric Signal Transmission Based on Measured Body Impulse Response

Authors
Kang, T.Kim, S.Oh, K.-I.Hwang, J.-H.Lee, J.Park, H.Byun, K.Lee, W.
Issue Date
Sep-2020
Publisher
Institute of Electrical and Electronics Engineers Inc.
Keywords
Channel measurement; channel modeling; human body channel; human body communications (HBCs); sensor networks; wearable device; wireless body area networks (WBANs)
Citation
IEEE Transactions on Instrumentation and Measurement, v.69, no.9, pp 6399 - 6411
Pages
13
Journal Title
IEEE Transactions on Instrumentation and Measurement
Volume
69
Number
9
Start Page
6399
End Page
6411
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/63271
DOI
10.1109/TIM.2020.2970870
ISSN
0018-9456
1557-9662
Abstract
Human body communications (HBCs) have recently emerged as an innovative alternative to the current radio frequency communications for realizing wireless body area networks (WBANs) using the human body as a transmission channel without wired or wireless connections. This article addresses the provision of reliable modeling of the human body as a passage of the electric signal delivery based on the impulse response measurement through the proposal of a measurement setup and signal processing techniques applicable to wearable devices for healthcare and biosignal acquisition. In the experiments, customized impulse signals were applied to the body using battery-powered devices isolated to the earth ground for the operating environments of wearable devices. The impulse responses passed through the body were measured by considering 52 measurement conditions determined by the device locations from the head to ankle and the body postures. Body channel transfer functions (BCTFs) for the respective conditions were derived by an adaptive filter approach using an iterative algorithm to minimize the mean squared error between the measured and modeled impulse responses. The channel analysis parameters, such as mean path loss, root-mean-square delay spread, and mean and maximum excess delays, were analyzed based on the measured body impulse responses. In addition, the practical bit-error-rate performance for HBC based on the BCTFs reproducing intersymbol interference effects caused by the delay spreads of the body channels was explored to verify communication reliability in terms of the transmitter structures adopting digital transmission, sorts of human body channels, data rates, and operating frequencies. © 1963-2012 IEEE.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of ICT Engineering > School of Electrical and Electronics Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Woo Joo photo

Lee, Woo Joo
창의ICT공과대학 (전자전기공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE