Evaluation of the plan delivery accuracy of intensity-modulated radiation therapy by texture analysis using fluence maps
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, S.-Y. | - |
dc.contributor.author | Kim, J.-I. | - |
dc.contributor.author | Oh, D.H. | - |
dc.contributor.author | Park, J.M. | - |
dc.date.accessioned | 2023-03-08T15:04:43Z | - |
dc.date.available | 2023-03-08T15:04:43Z | - |
dc.date.issued | 2019-03 | - |
dc.identifier.issn | 1120-1797 | - |
dc.identifier.issn | 1724-191X | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/63763 | - |
dc.description.abstract | Purpose: The aim of this study is to evaluate the plan delivery accuracy of intensity-modulated radiation therapy (IMRT) by using textural features calculated from fluence maps. Methods: In total, 202 IMRT plans were generated with the Trilogy (C-series linac) and TrueBeam STx systems. Fluence maps were obtained for each IMRT plan. With the fluence map, six textural features were calculated, namely angular second moment (ASM), inverse difference moment (IDM), contrast, variance, correlation, and entropy (particular displacement distances, d = 1, 5, and 10). To evaluate performances of textural features in predicting IMRT delivery accuracy, Spearman's rank correlation coefficients (r s ) were calculated between textural feature values and measures of conventional methods. Results: For Trilogy, correlation (d = 1) showed r s values of −0.764 (p < 0.001) with gamma passing rates of 2%/1 mm and 0.863 (p < 0.001) with multi-leaf collimator (MLC) errors. For TrueBeam STx, variance (d = 10) showed r s values of 0.691 (p < 0.001) with gamma passing rates of 1%/2 mm and −0.585 (p < 0.001) with MLC errors. Conclusion: Correlation (d = 1) for Trilogy and variance (d = 10) for TrueBeam STx demonstrated the potential in predicting IMRT delivery accuracy with high correlations to conventional IMRT delivery accuracy measures. © 2019 Associazione Italiana di Fisica Medica | - |
dc.format.extent | 11 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Associazione Italiana di Fisica Medica | - |
dc.title | Evaluation of the plan delivery accuracy of intensity-modulated radiation therapy by texture analysis using fluence maps | - |
dc.type | Article | - |
dc.identifier.doi | 10.1016/j.ejmp.2019.02.016 | - |
dc.identifier.bibliographicCitation | Physica Medica, v.59, pp 64 - 74 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000462466400008 | - |
dc.identifier.scopusid | 2-s2.0-85062302834 | - |
dc.citation.endPage | 74 | - |
dc.citation.startPage | 64 | - |
dc.citation.title | Physica Medica | - |
dc.citation.volume | 59 | - |
dc.type.docType | Article | - |
dc.publisher.location | 영국 | - |
dc.subject.keywordAuthor | Fluence | - |
dc.subject.keywordAuthor | Intensity-modulated radiation therapy | - |
dc.subject.keywordAuthor | Modulation index | - |
dc.subject.keywordAuthor | Texture analysis | - |
dc.subject.keywordPlus | RADIOTHERAPY | - |
dc.subject.keywordPlus | IMRT | - |
dc.subject.keywordPlus | VMAT | - |
dc.subject.keywordPlus | DOSIMETRY | - |
dc.subject.keywordPlus | FEATURES | - |
dc.subject.keywordPlus | ERRORS | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.