On-Site Application of Novel Partial Discharge Monitoring Scheme for Rotating Machine
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Yong Joo | - |
dc.contributor.author | Hong, Seok Hoon | - |
dc.contributor.author | Kong, Tae Sik | - |
dc.contributor.author | Kim, Hee Dong | - |
dc.date.accessioned | 2023-03-08T19:42:08Z | - |
dc.date.available | 2023-03-08T19:42:08Z | - |
dc.date.issued | 2014 | - |
dc.identifier.issn | 0000-0000 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/64706 | - |
dc.description.abstract | Authors' previous work had introduced a novel on-line partial discharge monitoring sensor CSC (Capacitive Slot Coupler), which frequency band was claimed to be between 100 kHz and 20 MHz. However, after intensive laboratory work and on-site experiment, it was found that frequency characteristic of CSC PD sensor could be widely extended from 100 kHz up to 250 MHz. Furthermore, from on-site experiment for small motor, it suggests that the novel CSC PD sensor could be adopted in effectively discriminating the various external noises and locating PD activity. In addition, it is confirmed that partial discharge signals detected by CSC is compatibly adapted to the commercial on-line PD monitoring systems. | - |
dc.format.extent | 4 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | IEEE | - |
dc.title | On-Site Application of Novel Partial Discharge Monitoring Scheme for Rotating Machine | - |
dc.type | Article | - |
dc.identifier.doi | 10.1109/ICACACT.2014.7223551 | - |
dc.identifier.bibliographicCitation | 2015 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), pp 85 - 88 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000371481800017 | - |
dc.identifier.scopusid | 2-s2.0-84978434520 | - |
dc.citation.endPage | 88 | - |
dc.citation.startPage | 85 | - |
dc.citation.title | 2015 IEEE ELECTRICAL INSULATION CONFERENCE (EIC) | - |
dc.type.docType | Proceedings Paper | - |
dc.subject.keywordAuthor | partial discharge | - |
dc.subject.keywordAuthor | stator bar | - |
dc.subject.keywordAuthor | on-line monitoring | - |
dc.subject.keywordAuthor | external noise disrimination | - |
dc.subject.keywordAuthor | partial discharge locating technique | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.