Position calibration of silicon strip detector using quasi-elastic scattering of 16O+197Au
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yan, W. | - |
dc.contributor.author | Hu, H. | - |
dc.contributor.author | Zhang, G. | - |
dc.contributor.author | Lin, C. | - |
dc.contributor.author | Zhang, H. | - |
dc.contributor.author | Zhang, C. | - |
dc.contributor.author | Jia, H. | - |
dc.contributor.author | An, G. | - |
dc.contributor.author | Wu, Z. | - |
dc.contributor.author | Xu, X. | - |
dc.contributor.author | Yang, F. | - |
dc.contributor.author | Liu, Z. | - |
dc.contributor.author | Kubono, S. | - |
dc.contributor.author | Yamaguchi, H. | - |
dc.contributor.author | Hayakawa, S. | - |
dc.contributor.author | Binh, D.N. | - |
dc.contributor.author | Kwon, Y.K. | - |
dc.contributor.author | Iwasa, N. | - |
dc.contributor.author | Mazzocco, M. | - |
dc.contributor.author | Commara La, M. | - |
dc.contributor.author | Romoli, M. | - |
dc.contributor.author | Signorini, C. | - |
dc.date.accessioned | 2023-03-08T21:37:50Z | - |
dc.date.available | 2023-03-08T21:37:50Z | - |
dc.date.issued | 2013-08 | - |
dc.identifier.issn | 0253-3219 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/64909 | - |
dc.description.abstract | Background: Elastic scattering is induced by weakly unstable nuclei. Generally, a good angular resolution for angular distribution of elastic scattering is needed. The silicon strip detector is often used for this kind of experiment. Purpose: In order to use silicon strip detector to study the elastic scattering of weakly unbound nuclei, it is important to get the information of its position calibration. It is well known that the elastic scattering of stable nuclei has a good angular distribution and many experimental data have been obtained. Methods: So the scattering of stable nuclei can be used to calibrate the position information of silicon strip detector. In this experiment, the positions of silicon strip detectors are calibrated using 101 MeV and 59 MeV 16O scattering on the 197Au target. Results: The quasi-elastic peaks can be observed in the silicon strip detectors and the counts of quasi-elastic 16O can be obtained. The solid angles of the silicon strip detectors are calibrated by using alpha source which has three alpha energy values. The angular distribution of quasi-elastic scattering of 16O+197Au is obtained at these two energy values. Conclusions: The experimental data of angular distribution are reasonable and fit for the principle of angular distribution of elastic scattering. It is concluded that in the experiment these silicon strip detectors can accurately give the position information and can be used for the elastic scattering experiment. | - |
dc.language | 중국어 | - |
dc.language.iso | CHI | - |
dc.title | Position calibration of silicon strip detector using quasi-elastic scattering of 16O+197Au | - |
dc.type | Article | - |
dc.identifier.bibliographicCitation | He Jishu/Nuclear Techniques, v.36, no.8 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.scopusid | 2-s2.0-84885074636 | - |
dc.citation.number | 8 | - |
dc.citation.title | He Jishu/Nuclear Techniques | - |
dc.citation.volume | 36 | - |
dc.type.docType | Article | - |
dc.publisher.location | 대만 | - |
dc.subject.keywordAuthor | Angular distribution | - |
dc.subject.keywordAuthor | Quasi-elastic scattering | - |
dc.subject.keywordAuthor | Silicon strip detector | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.