Analysis of contact loss arc spectrum between contact wire and pantograph material using a spectrometerAnalysis of Contact Loss Arc Spectrum between Contact Wire and Pantograph Material using a Spectrometer
- Authors
- 장진영; 정노건; 박종국; 구경완; 김재문
- Issue Date
- Dec-2013
- Publisher
- 대한전기학회
- Keywords
- Arc discharge detection; Contact loss; Contact wire; Pantograph; Ultraviolet rays
- Citation
- Transactions of the Korean Institute of Electrical Engineers, v.62, no.12, pp 1803 - 1808
- Pages
- 6
- Journal Title
- Transactions of the Korean Institute of Electrical Engineers
- Volume
- 62
- Number
- 12
- Start Page
- 1803
- End Page
- 1808
- URI
- https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/64920
- DOI
- 10.5370/KIEE.2013.62.12.1803
- ISSN
- 1975-8359
2287-4364
- Abstract
- To maintain contact between catenary and pantograph copper is important in order to transmit power smoothly on Current collection system. But, Arc discharge with strong light is generated because of contact loss. Therefore, Arc discharge detection is important measurement factor judging performance of current collection system. In this paper, It is described to results of arc discharge applying UV detection technology using arc generator. And Arc discharge was detected using the most commonly used processing catenary and rigid catenary and pantograph copper of electric rolling stock for securing arc detection instrument reliability. Results of contact loss detection instrument in this paper will be used for maintenance of current collection quality and system.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of ICT Engineering > School of Electrical and Electronics Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.