Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Metal CMP 세정 공정에서 DHF 적용에 관한 연구Investigation on DHF Application at Metal CMP Cleaning Process

Authors
김상용김남훈김인표장의구
Issue Date
Apr-2003
Publisher
한국전기전자재료학회
Keywords
DHF; Barrier metal; Oxide loss; Residue; Metal contamination
Citation
전기전자재료학회논문지, v.16, no.7
Journal Title
전기전자재료학회논문지
Volume
16
Number
7
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/65696
ISSN
1226-7945
Abstract
In this study, we evaluated the dilute HF cleaning to reduce residual defects made by metal CMP process. The purpose of this test is to observe the existence of barrier metal damage during DHF cleaning on condition that it should not affect metal thin film reliability, so we will get rid of slurry residual particles as a main defect of the metal CMP process for the better yield. In-line defect data showed us that slurry residual particles were removed by DHF application. The HF rinse significantly reduced metal contamination levels and surface roughness. The best effect by additional oxide loss was discovered when Dilute HF condition is 10".
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of ICT Engineering > School of Electrical and Electronics Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE