Analysis of minimum noise range for signal detection method using 2w harmonic frequency in biosensor signal detection
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jeon, Su-Jin | - |
dc.contributor.author | Kim, JiHoon | - |
dc.contributor.author | Ji, Myung-Gi | - |
dc.contributor.author | Park, Jun-Hee | - |
dc.contributor.author | Choi, Young Wan | - |
dc.date.accessioned | 2023-07-25T04:42:30Z | - |
dc.date.available | 2023-07-25T04:42:30Z | - |
dc.date.issued | 2016-10 | - |
dc.identifier.issn | 2384-2113 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/67268 | - |
dc.description.abstract | Recently, biosensors have been developed for portable biosensor system. Signals measured in the biosensor system are inevitably accompanied by a variety of internal and external noises. Thus, biosensor systems require very low-level signals detection under noisy environments. Lock-in amplifier (LIA) has been used for the detection of a weak signal concealed in an intense background noise such as thermal noise, flicker noise (1/f) and shot noise in biosensor systems. The LIA is composed of a trans-impedance amplifier (TIA), a phase sensitive detector (PSD) and filters such as low pass filter (LPF) and high pass filter (HPF). In general, output signal of the LIA is that modulated signal by the PSD is represented by the DC voltage after passing through the LPF. However, in order to improve the signal to noise ratio (SNR) and dynamic reserve, a second-order harmonic frequency (2 c) which is double of reference frequency is used. For the detection of 2 c signal, the minimum noise region in frequency domain should be determined. Also, this region should not be affected by the flicker noise. The total noise characteristics of a system almost depend on the first stage of cascade system by Friis formulas. Therefore, total noise figure of the LIA is determined by the noise characteristics of the TIA. In this paper, we analyzed characteristics of the TIA and found the minimum noise region for using 2 c detection method. We implemented the LIA based on CMOS integrated circuit using 0.18㎛ process and detected the 2 c signal for improvement of the SNR. As a result of experiment, the minimum noise region is ranged from 20 to 55㎑ in the TIA. | - |
dc.format.extent | 7 | - |
dc.publisher | 반도체설계교육센터 | - |
dc.title | Analysis of minimum noise range for signal detection method using 2w harmonic frequency in biosensor signal detection | - |
dc.title.alternative | Analysis of minimum noise range for signal detection method using 2 harmonic frequency in biosensor signal detection | - |
dc.type | Article | - |
dc.identifier.doi | 10.23075/jicas.2016.2.3.002 | - |
dc.identifier.bibliographicCitation | IDEC Journal of Integrated Circuits and Systems, v.02, no.3, pp 7 - 13 | - |
dc.identifier.kciid | ART002653738 | - |
dc.description.isOpenAccess | N | - |
dc.citation.endPage | 13 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 7 | - |
dc.citation.title | IDEC Journal of Integrated Circuits and Systems | - |
dc.citation.volume | 02 | - |
dc.publisher.location | 대한민국 | - |
dc.description.journalRegisteredClass | domestic | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.