Tunable image quality control of 3-D ultrasound using switchable CycleGAN

Full metadata record
DC Field Value Language
dc.contributor.authorHuh, Jaeyoung-
dc.contributor.authorKhan, Shujaat-
dc.contributor.authorChoi, Sungjin-
dc.contributor.authorShin, Dongkuk-
dc.contributor.authorLee, Jeong Eun-
dc.contributor.authorLee, Eun Sun-
dc.contributor.authorChul, Jong-
dc.date.accessioned2023-11-22T01:41:32Z-
dc.date.available2023-11-22T01:41:32Z-
dc.date.issued2023-01-
dc.identifier.issn1361-8415-
dc.identifier.issn1361-8423-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/68632-
dc.description.abstractIn contrast to 2-D ultrasound (US) for uniaxial plane imaging, a 3-D US imaging system can visualize a volume along three axial planes. This allows for a full view of the anatomy, which is useful for gynecological (GYN) and obstetrical (OB) applications. Unfortunately, the 3-D US has an inherent limitation in resolution compared to the 2-D US. In the case of 3-D US with a 3-D mechanical probe, for example, the image quality is comparable along the beam direction, but significant deterioration in image quality is often observed in the other two axial image planes. To address this, here we propose a novel unsupervised deep learning approach to improve 3-D US image quality. In particular, using unmatched high-quality 2-D US images as a reference, we trained a recently proposed switchable CycleGAN architecture so that every mapping plane in 3-D US can learn the image quality of 2-D US images. Thanks to the switchable architecture, our network can also provide real-time control of image enhancement level based on user preference, which is ideal for a user-centric scanner setup. Extensive experiments with clinical evaluation confirm that our method offers significantly improved image quality as well user-friendly flexibility.-
dc.language영어-
dc.language.isoENG-
dc.publisherELSEVIER-
dc.titleTunable image quality control of 3-D ultrasound using switchable CycleGAN-
dc.typeArticle-
dc.identifier.doi10.1016/j.media.2022.102651-
dc.identifier.bibliographicCitationMEDICAL IMAGE ANALYSIS, v.83-
dc.description.isOpenAccessN-
dc.identifier.wosid000882633500002-
dc.identifier.scopusid2-s2.0-85142717917-
dc.citation.titleMEDICAL IMAGE ANALYSIS-
dc.citation.volume83-
dc.type.docTypeArticle; Early Access-
dc.publisher.location네델란드-
dc.subject.keywordAuthor3-D ultrasound imaging-
dc.subject.keywordAuthorDeep learning-
dc.subject.keywordAuthorAdaptive Instance Normalization (AdaIN)-
dc.subject.keywordAuthorObstetrics and gynecology-
dc.relation.journalResearchAreaComputer Science-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryComputer Science, Artificial Intelligence-
dc.relation.journalWebOfScienceCategoryComputer Science, Interdisciplinary Applications-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Eun Sun photo

Lee, Eun Sun
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE