Evaluation of the pull-out strength of connections with roof cladding using honeycomb panels with cool roof performance capacity
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Sang-Woo | - |
dc.contributor.author | Lee, In-Ho | - |
dc.contributor.author | Ko, Kwang-Il | - |
dc.contributor.author | Lee, E. T. | - |
dc.date.available | 2019-03-08T12:58:20Z | - |
dc.date.issued | 2016-06 | - |
dc.identifier.issn | 1598-2351 | - |
dc.identifier.issn | 2093-6311 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/6912 | - |
dc.description.abstract | The roof cladding of buildings requires measurement of the 'screw pull-out' by typhoons that can cause casualties and property damage. From this study, we increased the pull-out resistance was increased by increasing the penetration depth of the ironware installation screw, called an 'nut insert', on the roof cladding frame. We conducted a tensile test to compare the pull-out strengths of a general screw joint and a nut insert joint. Actual roof cladding to be used was produced in the field using the 'Solid Work' analysis program, then compared the roof claddings using a general screw joint and a nut insert joint by a static test and dynamic test. | - |
dc.format.extent | 12 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | KOREAN SOC STEEL CONSTRUCTION-KSSC | - |
dc.title | Evaluation of the pull-out strength of connections with roof cladding using honeycomb panels with cool roof performance capacity | - |
dc.type | Article | - |
dc.identifier.doi | 10.1007/s13296-016-6020-2 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF STEEL STRUCTURES, v.16, no.2, pp 505 - 516 | - |
dc.identifier.kciid | ART002125017 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000379535000020 | - |
dc.identifier.scopusid | 2-s2.0-84978179942 | - |
dc.citation.endPage | 516 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 505 | - |
dc.citation.title | INTERNATIONAL JOURNAL OF STEEL STRUCTURES | - |
dc.citation.volume | 16 | - |
dc.type.docType | Article | - |
dc.publisher.location | 대한민국 | - |
dc.subject.keywordAuthor | pull-out strength | - |
dc.subject.keywordAuthor | screw | - |
dc.subject.keywordAuthor | nut insert | - |
dc.subject.keywordAuthor | roof cladding | - |
dc.subject.keywordAuthor | static test | - |
dc.subject.keywordAuthor | dynamic test | - |
dc.relation.journalResearchArea | Construction & Building Technology | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Construction & Building Technology | - |
dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.