Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Extent of vertical cementing as a predictive factor for radiolucency in revision total knee arthroplasty

Full metadata record
DC Field Value Language
dc.contributor.authorRo, Du Hyun-
dc.contributor.authorCho, Yool-
dc.contributor.authorLee, Sahnghoon-
dc.contributor.authorChung, Kee Yun-
dc.contributor.authorKim, Seong Hwan-
dc.contributor.authorLee, Young Min-
dc.contributor.authorLee, Joon Kyu-
dc.contributor.authorLee, Myung Chul-
dc.date.accessioned2024-01-09T13:37:15Z-
dc.date.available2024-01-09T13:37:15Z-
dc.date.issued2016-08-
dc.identifier.issn0942-2056-
dc.identifier.issn1433-7347-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/70309-
dc.description.abstractLimited information is available regarding the effects of cementing extent on implant stability in patients who have undergone revision total knee arthroplasty (TKA). As such, the goals of this study were: (1) to determine the correlation between the extent of vertical cementing and implant loosening; (2) to determine whether the extent of cementing is a potential predictive factor for radiolucency; and (3) to evaluate the minimal amount of cement needed for a stable implant during revision TKA using a hybrid technique. One hundred nine stemmed/revision TKAs with a mean follow-up period of 5 years were retrospectively analysed. In each case, a single varus-valgus constrained implant was used and fixed with a hybrid technique. Implant stability was evaluated according to the modified Knee Society radiographic scoring system. The extent of vertical cementing was defined as the longitudinal length from the implant base to the end of the radiopaque line around the stem on radiograph. Its correlation with implant stability was analysed, and the minimal value for a stable implant was evaluated with a receiver operating characteristic (ROC) analysis. The mean extent of vertical cementing was longer in stable implants (femur: p = 0.001, tibia: p = 0.004) and significantly correlated with implant stability (femur: p < 0.001, tibia: p = 0.001). A logistic regression analysis revealed that the risk of loosening was 8.7-16.1 times higher when the extent of cementing was < 40 mm, which was located at the stem-implant junction of the modular implant. The minimal extent of vertical cementing was estimated to be 60 mm for a stable femoral implant and 50 mm for a tibial implant. The hybrid fixation technique with a cementing extent > 60 mm for the femur and 50 mm for the tibia was durable at a mean follow-up period of 5 years. Vertical cementing 10-20 mm above the stem-implant junction is recommended when performing revision TKA using this technique. IV.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherSPRINGER-
dc.titleExtent of vertical cementing as a predictive factor for radiolucency in revision total knee arthroplasty-
dc.typeArticle-
dc.identifier.doi10.1007/s00167-016-4011-7-
dc.identifier.bibliographicCitationKNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, v.24, no.8, pp 2710 - 2717-
dc.description.isOpenAccessN-
dc.identifier.wosid000380713600046-
dc.identifier.scopusid2-s2.0-84982694784-
dc.citation.endPage2717-
dc.citation.number8-
dc.citation.startPage2710-
dc.citation.titleKNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY-
dc.citation.volume24-
dc.type.docTypeArticle-
dc.publisher.location미국-
dc.subject.keywordAuthorRevision total knee arthroplasty-
dc.subject.keywordAuthorCement extent-
dc.subject.keywordAuthorHybrid fixation-
dc.subject.keywordAuthorStem-
dc.subject.keywordPlusBONE-MINERAL DENSITY-
dc.subject.keywordPlusCOMPONENT STABILITY-
dc.subject.keywordPlusTIBIAL COMPONENT-
dc.subject.keywordPlusSTEM FIXATION-
dc.subject.keywordPlusREPLACEMENT-
dc.subject.keywordPlusALLOGRAFT-
dc.subject.keywordPlusREGISTRY-
dc.subject.keywordPlusKOREA-
dc.relation.journalResearchAreaOrthopedics-
dc.relation.journalResearchAreaSport Sciences-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategoryOrthopedics-
dc.relation.journalWebOfScienceCategorySport Sciences-
dc.relation.journalWebOfScienceCategorySurgery-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Seong Hwan photo

Kim, Seong Hwan
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE