Diagnostic proficiency test using digital cytopathology and comparative assessment of whole slide images of cytologic samples for quality assurance program in Korea

Full metadata record
DC Field Value Language
dc.contributor.author정요셉-
dc.contributor.author홍순억-
dc.contributor.author오훈규-
dc.contributor.author정수진-
dc.contributor.author김보성-
dc.contributor.author정지윤-
dc.contributor.author이호창-
dc.contributor.author공경엽-
dc.date.accessioned2024-01-09T14:35:31Z-
dc.date.available2024-01-09T14:35:31Z-
dc.date.issued2023-09-
dc.identifier.issn2383-7837-
dc.identifier.issn2383-7845-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/70494-
dc.description.abstractBackground: The Korean Society for Cytopathology introduced a digital proficiency test (PT) in 2021. However, many doubtful opinions remain on whether digitally scanned images can satisfactorily present subtle differences in the nuclear features and chromatin patterns of cytological samples. Methods: We prepared 30 whole-slide images (WSIs) from the conventional PT archive by a selection process for digital PT. Digital and conventional PT were performed in parallel for volunteer institutes, and the results were compared using feedback. To assess the quality of cytological assessment WSIs, 12 slides were collected and scanned using five different scanners, with four cytopathologists evaluating image quality through a questionnaire. Results: Among the 215 institutes, 108 and 107 participated in glass and digital PT, respectively. No significant difference was noted in category C (major discordance), although the number of discordant cases was slightly higher in the digital PT group. Leica, 3DHistech Pannoramic 250 Flash, and Hamamatsu NanoZoomer 360 systems showed comparable results in terms of image quality, feature presentation, and error rates for most cytological samples. Overall satisfaction was observed with the general convenience and image quality of digital PT. Conclusions: As three-dimensional clusters are common and nuclear/chromatin features are critical for cytological interpretation, careful selection of scanners and optimal conditions are mandatory for the successful establishment of digital quality assurance programs in cytology.-
dc.format.extent14-
dc.language영어-
dc.language.isoENG-
dc.publisher대한병리학회-
dc.titleDiagnostic proficiency test using digital cytopathology and comparative assessment of whole slide images of cytologic samples for quality assurance program in Korea-
dc.typeArticle-
dc.identifier.doi10.4132/jptm.2023.07.17-
dc.identifier.bibliographicCitationJournal of Pathology and Translational Medicine, v.57, no.5, pp 251 - 264-
dc.identifier.kciidART002996339-
dc.description.isOpenAccessY-
dc.identifier.wosid001071164800001-
dc.identifier.scopusid2-s2.0-85175449528-
dc.citation.endPage264-
dc.citation.number5-
dc.citation.startPage251-
dc.citation.titleJournal of Pathology and Translational Medicine-
dc.citation.volume57-
dc.type.docTypeArticle-
dc.publisher.location대한민국-
dc.subject.keywordAuthorCytology-
dc.subject.keywordAuthorQuality assurance-
dc.subject.keywordAuthorDigital pathology-
dc.subject.keywordAuthorWhole-slide image-
dc.subject.keywordAuthorWhole-slide scanner-
dc.relation.journalResearchAreaPathology-
dc.relation.journalWebOfScienceCategoryPathology-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClassesci-
dc.description.journalRegisteredClasskci-
Files in This Item
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, Soon Uk photo

Hong, Soon Uk
의과대학 (의학부(기초))
Read more

Altmetrics

Total Views & Downloads

BROWSE