Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Dichotomous versus 5-scale grading system for the interpretation of the point-of-care immunoassay for tear matrix metalloproteinase-9 in dry eye

Full metadata record
DC Field Value Language
dc.contributor.authorOh, Ja Young-
dc.contributor.authorChun, Yeoun Sook-
dc.contributor.authorKim, Kyoung Woo-
dc.date.accessioned2024-01-11T02:01:17Z-
dc.date.available2024-01-11T02:01:17Z-
dc.date.issued2023-04-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/70947-
dc.description.abstractIn this study, we compared the dichotomous and 5-scale grading systems for point-of-care immunoassay of tear matrix metalloproteinase (MMP)-9 in dry eye disease (DED) patients and identified the optimal dichotomous system to correlate with DED parameters. We included 167 DED patients without primary Sjogren's syndrome (pSS) (Non-SS DED) and 70 DED patients with pSS (SS DED). We graded MMP-9 expression in InflammaDry® (Quidel, San Diego, CA, USA) using a 5-scale grading system and dichotomous grading systems with four different cut-off grades (D1 to D4 systems). The only DED parameter that showed a significant correlation with the 5-scale grading method was tear osmolarity (Tosm). In both groups, subjects with positive MMP-9 had lower tear secretion and higher Tosm than those with negative MMP-9 according to the D2 dichotomous system. Tosm determined D2 positivity at cutoffs > 340.5 and > 317.5 mOsm/L in the Non-SS DED and SS DED groups, respectively. Tear secretion < 10.5 mm or tear break-up time < 5.5 s stratified D2 positivity in the Non-SS DED group. In conclusion, the dichotomous grading system of InflammaDry reflects ocular surface indices better than the 5-scale grading system and may be more practical in real clinical circumstances. © 2023. The Author(s).-
dc.language영어-
dc.language.isoENG-
dc.publisherNLM (Medline)-
dc.titleDichotomous versus 5-scale grading system for the interpretation of the point-of-care immunoassay for tear matrix metalloproteinase-9 in dry eye-
dc.typeArticle-
dc.identifier.doi10.1038/s41598-023-32928-3-
dc.identifier.bibliographicCitationScientific reports, v.13, no.1-
dc.description.isOpenAccessY-
dc.identifier.wosid000984454500087-
dc.identifier.scopusid2-s2.0-85152473508-
dc.citation.number1-
dc.citation.titleScientific reports-
dc.citation.volume13-
dc.type.docTypeArticle-
dc.publisher.location영국-
dc.subject.keywordPlusOCULAR SURFACE-
dc.subject.keywordPlusMATRIX METALLOPROTEINASES-
dc.subject.keywordPlusDOXYCYCLINE-
dc.subject.keywordPlusEXPRESSION-
dc.subject.keywordPlusMMP-9-
dc.subject.keywordPlusCLASSIFICATION-
dc.subject.keywordPlusINFLAMMATION-
dc.subject.keywordPlusCYTOKINES-
dc.subject.keywordPlusDIAGNOSIS-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Kyoung Woo photo

Kim, Kyoung Woo
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE