Smartwatches as chest compression feedback devices: A feasibility study

Full metadata record
DC Field Value Language
dc.contributor.authorSong, Yeongtak-
dc.contributor.authorChee, Youngjoon-
dc.contributor.authorOh, Jaehoon-
dc.contributor.authorAhn, Chiwon-
dc.contributor.authorLim, Tae Ho-
dc.date.accessioned2024-01-18T05:01:27Z-
dc.date.available2024-01-18T05:01:27Z-
dc.date.issued2016-06-
dc.identifier.issn0300-9572-
dc.identifier.issn1873-1570-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/71054-
dc.description.abstractBackground: Recently, there have been attempts to use smartphones and smartwatches as the feedback devices to improve the quality of chest compressions. In this study, we compared chest compression depth feedback accuracy between a smartphone and a smartwatch in a hands-only cardiopulmonary resuscitation scenario, using a manikin with a displacement sensor system. Methods: Ten basic life support providers participated in this study. Guided by the chest compression depths displayed on the monitor of a laptop, which received data from the manikin, each participant performed 2 min of chest compressions for each target depth (35 mm and 55 mm) on a manikin while gripping a smartphone and wearing a smartwatch. Participants had a rest of 1 h between the instances, and the first target depth was set at random. Each chest compression depth data value from the smartphone and smartwatch and a corresponding reference value from the manikin with the displacement system were recorded. To compare the accuracy between the smartphone and smartwatch, the errors, expressed as the absolute of the differences between the reference and each device, were calculated. Results: At both target depths, the error of the smartwatch were significantly smaller than that of the smartphone (the errors of the smartphone vs. smartwatch at 35 mm: 3.4 (1.3) vs. 2.1 (0.8) mm; p = 0.008; at 55 mm: 5.3 (2.8) vs. 2.3 (0.9) mm; p = 0.023). Conclusion: The smartwatch-based chest compression depth feedback was more accurate than smartphone-based feedback. (C) 2016 Elsevier Ireland Ltd. All rights reserved.-
dc.format.extent4-
dc.language영어-
dc.language.isoENG-
dc.publisherELSEVIER IRELAND LTD-
dc.titleSmartwatches as chest compression feedback devices: A feasibility study-
dc.typeArticle-
dc.identifier.doi10.1016/j.resuscitation.2016.03.014-
dc.identifier.bibliographicCitationRESUSCITATION, v.103, pp 20 - 23-
dc.description.isOpenAccessN-
dc.identifier.wosid000375898600016-
dc.identifier.scopusid2-s2.0-84961924284-
dc.citation.endPage23-
dc.citation.startPage20-
dc.citation.titleRESUSCITATION-
dc.citation.volume103-
dc.type.docTypeArticle-
dc.publisher.location아일랜드-
dc.subject.keywordAuthorCPR-
dc.subject.keywordAuthorChest compression-
dc.subject.keywordAuthorFeedback device-
dc.subject.keywordAuthorSmartphone-
dc.subject.keywordAuthorSmartwatch-
dc.subject.keywordPlusCARDIOPULMONARY-RESUSCITATION-
dc.subject.keywordPlusRESCUER FATIGUE-
dc.subject.keywordPlusCPR-
dc.subject.keywordPlusDEPTH-
dc.subject.keywordPlusQUALITY-
dc.subject.keywordPlusSMARTPHONE-
dc.subject.keywordPlusGUIDELINES-
dc.subject.keywordPlusMANNEQUIN-
dc.subject.keywordPlusAPPS-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalResearchAreaEmergency Medicine-
dc.relation.journalWebOfScienceCategoryCritical Care Medicine-
dc.relation.journalWebOfScienceCategoryEmergency Medicine-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ahn, Chiwon photo

Ahn, Chiwon
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE