Structural changes in the retina after implantation of subretinal three-dimensional implants in mini pigs

Full metadata record
DC Field Value Language
dc.contributor.authorVu, Que Anh-
dc.contributor.authorSeo, Hee Won-
dc.contributor.authorChoi, Kwang-Eon-
dc.contributor.authorKim, Namju-
dc.contributor.authorKang, Yoo Na-
dc.contributor.authorLee, Jaemeun-
dc.contributor.authorPark, Sun-Hyun-
dc.contributor.authorKim, Jee Taek-
dc.contributor.authorKim, Sohee-
dc.contributor.authorKim, Seong-Woo-
dc.date.accessioned2024-01-25T02:00:58Z-
dc.date.available2024-01-25T02:00:58Z-
dc.date.issued2022-09-
dc.identifier.issn1662-4548-
dc.identifier.issn1662-453X-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/71449-
dc.description.abstractThe retinal structural changes after subretinal implantation of three-dimensional (3D) microelectrodes were investigated in a mini pig. Three types of electrode were implanted into the subretinal spaces of nine mini pigs: 75-mu m-high 3D electrodes on a 200-mu m-thick right-angled polydimethylsiloxane (PDMS) substrate (group 1); a 140-mu m-thick sloped PDMS substrate without electrodes (group 2); and a 140-mu m-thick sloped PDMS substrate with 20-mu m-high 3D electrodes (group 3). One mini pig was used as a control. Spectral domain-optical coherence tomography (SD-OCT) images were obtained at baseline and 2, 6, and 12 weeks post-surgery. Retinal specimens were immunostained using a tissue-clearing method 3 months post-implantation. The 75-mu m-high 3D electrodes progressively penetrated the inner nuclear layer (INL) and touched the inner plexiform layer (IPL) 2 weeks post-surgery. At 6 weeks post-operatively, the electrodes were in contact with the nerve-fiber layer, accompanied by a severe fibrous reaction. In the other groups, the implants remained in place without subretinal migration. Immunostaining showed that retinal ganglion and bipolar cells were preserved without fibrosis over the retinal implants in groups 2 and 3 during the 12-week implantation period. In summary, SD-OCT and immunohistology results showed differences in the extent of reactions, such as fibrosis over the implants and penetration of the electrodes into the inner retinal layer depending on different types of electrodes. A sloped substrate performed better than a right-angled substrate in terms of retinal preservation over the implanted electrodes. The 20-mu m-high electrodes showed better structural compatibility than the 75-mu m-high 3D electrodes. There was no significant difference between the results of sloped implants without electrodes and 20-mu m-high 3D electrodes, indicating that the latter had no adverse effects on retinal tissue.-
dc.language영어-
dc.language.isoENG-
dc.publisherFRONTIERS MEDIA SA-
dc.titleStructural changes in the retina after implantation of subretinal three-dimensional implants in mini pigs-
dc.typeArticle-
dc.identifier.doi10.3389/fnins.2022.1010445-
dc.identifier.bibliographicCitationFRONTIERS IN NEUROSCIENCE, v.16-
dc.description.isOpenAccessY-
dc.identifier.wosid000869460100001-
dc.identifier.scopusid2-s2.0-85139921965-
dc.citation.titleFRONTIERS IN NEUROSCIENCE-
dc.citation.volume16-
dc.type.docTypeArticle-
dc.publisher.location스위스-
dc.subject.keywordAuthorretinal prosthesis-
dc.subject.keywordAuthorsubretinal implant-
dc.subject.keywordAuthorimplant design-
dc.subject.keywordAuthorstructural retinal change-
dc.subject.keywordAuthorthree-dimensional microelectrodes-
dc.subject.keywordPlusELECTRICAL-STIMULATION-
dc.subject.keywordPlusMICROELECTRODE ARRAY-
dc.subject.keywordPlusBLIND PATIENTS-
dc.subject.keywordPlusIN-VIVO-
dc.subject.keywordPlusPROSTHESIS-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusVISION-
dc.subject.keywordPlusTRIAL-
dc.relation.journalResearchAreaNeurosciences & Neurology-
dc.relation.journalWebOfScienceCategoryNeurosciences-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Jee Taek photo

Kim, Jee Taek
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE