Wave-controlled aliasing in parallel imaging (Wave-CAIPI): Accelerating speed for the MRI-based diagnosis of enhancing intracranial lesions compared to magnetization-prepared gradient echo
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Oh, Hyunji | - |
dc.contributor.author | Yim, Younghee | - |
dc.contributor.author | Chung, Mi Sun | - |
dc.contributor.author | Byun, Jun Soo | - |
dc.date.accessioned | 2024-02-07T01:30:39Z | - |
dc.date.available | 2024-02-07T01:30:39Z | - |
dc.date.issued | 2023-05 | - |
dc.identifier.issn | 1932-6203 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/71813 | - |
dc.description.abstract | Purpose We aimed to validate the diagnostic performance of accelerated post-contrast magnetization-prepared rapid gradient-echo (MPRAGE) using wave–controlled aliasing in parallel imaging (Wave-CAIPI) for enhancing intracranial lesions, compared with conventional MPRAGE. Methods A total of 233 consecutive patients who underwent post-contrast Wave-CAIPI and conventional MPRAGE (scan time: 2 min 39 s vs. 4 min 30 s) were retrospectively evaluated. Two radiologists independently assessed whole images for the presence and diagnosis of enhancing lesions. The diagnostic performance for non-enhancing lesions, quantitative parameters (diameter of enhancing lesions, signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], and contrast rate), qualitative parameters (grey-white matter differentiation and conspicuity of enhancing lesions), and image qualities (overall image quality and motion artifacts) were also surveyed. The weighted kappa and percent agreement were used to evaluate the diagnostic agreement between the two sequences. Results Wave-CAIPI MPRAGE achieved significantly high agreement for the detection (98.7%[460/ 466], κ = 0.965) and diagnosis (97.8%[455/466], κ = 0.955) of enhancing intracranial lesions with conventional MPRAGE in pooled analysis. Detection and diagnosis of non-enhancing lesions (97.6% and 96.9% agreement), and diameter of enhancing lesions (P>0.05) also demonstrated high agreements between two sequences. Although Wave-CAIPI MPRAGE show lower SNR (P<0.01) than conventional MRAGE, it fulfilled comparable CNR (P = 0.486) and higher contrast rate (P<0.01). The qualitative parameters show similar value (P>0.05). The overall image quality was slightly poor, however, motion artifacts were better in Wave-CAIPI MPRAGE (both P = 0.005). Conclusion Wave-CAIPI MPRAGE provides reliable diagnostic performance for enhancing intracranial lesions within half of the scan time compared with conventional MPRAGE. © 2023 Oh et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Public Library of Science | - |
dc.title | Wave-controlled aliasing in parallel imaging (Wave-CAIPI): Accelerating speed for the MRI-based diagnosis of enhancing intracranial lesions compared to magnetization-prepared gradient echo | - |
dc.type | Article | - |
dc.identifier.doi | 10.1371/journal.pone.0285089 | - |
dc.identifier.bibliographicCitation | PLoS ONE, v.18, no.5 MAY | - |
dc.description.isOpenAccess | Y | - |
dc.identifier.wosid | 001024713900001 | - |
dc.identifier.scopusid | 2-s2.0-85158816143 | - |
dc.citation.number | 5 MAY | - |
dc.citation.title | PLoS ONE | - |
dc.citation.volume | 18 | - |
dc.type.docType | Article | - |
dc.publisher.location | 미국 | - |
dc.subject.keywordPlus | MP-RAGE SEQUENCES | - |
dc.subject.keywordPlus | CONSENSUS RECOMMENDATIONS | - |
dc.subject.keywordPlus | RESPONSE ASSESSMENT | - |
dc.subject.keywordPlus | BRAIN | - |
dc.subject.keywordPlus | METASTASES | - |
dc.subject.keywordPlus | PROTOCOL | - |
dc.subject.keywordPlus | CRITERIA | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalWebOfScienceCategory | Multidisciplinary Sciences | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.