Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Diagnosis of intracranial lesions using accelerated 3D T1 MPRAGE with wave-CAIPI technique: comparison with conventional 3D T1 MPRAGE

Full metadata record
DC Field Value Language
dc.contributor.authorLee, E.J.-
dc.contributor.authorKim, M.G.-
dc.contributor.authorChung, M.S.-
dc.contributor.authorKim, S.-O.-
dc.contributor.authorByun, J.S.-
dc.contributor.authorYim, Y.-
dc.date.accessioned2024-02-07T01:30:43Z-
dc.date.available2024-02-07T01:30:43Z-
dc.date.issued2022-12-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/71814-
dc.description.abstractWe aimed to evaluate the agreement in the diagnosis of intracranial lesions between conventional pre-contrast 3D T1 magnetization-prepared rapid gradient echo (MPRAGE) and wave-CAIPI (wave-controlled aliasing in parallel imaging) MPRAGE. Institutional review board approval was obtained and informed consent was waived for this retrospective study. We included 149 consecutive patients who had undergone brain MR with both conventional MPRAGE (scan time: 5 min 42 s) and wave-CAIPI MPRAGE (scan time: 2 min 44 s) from February to June 2018. All images were independently reviewed by two radiologists for the diagnosis of intracranial lesion and scored image quality using visual analysis. One technician measured signal-to-noise ratio. The agreement for diagnosis of intracranial lesion was calculated, and the intra- and interobserver agreements were analyzed by using kappa value. For the diagnosis of intracranial lesion, the conventional and wave-CAIPI MPRAGE demonstrated 99.7% of agreement (297 of 298) in the pooled analysis with very good agreement (k = 0.994). Intra- and inter-observer agreement showed very good (k > 0.9 in all) and good (k > 0.75) agreement, respectively. In the quantitative analysis, the signal-to-noise ratio had no difference (P > 0.05 for all). The overall image quality was poorer in images of wave-CAIPI MPRAGE (P < 0.001), but motion artifact had no difference between two sequences (P = 0.06). Compared to conventional MPRAGE, pre-contrast 3D T1 wave-CAIPI MPRAGE achieved higher agreement for the diagnosis of intracranial lesions and reduced the scan time by approximately 50%. © 2022, The Author(s).-
dc.language영어-
dc.language.isoENG-
dc.publisherNature Research-
dc.titleDiagnosis of intracranial lesions using accelerated 3D T1 MPRAGE with wave-CAIPI technique: comparison with conventional 3D T1 MPRAGE-
dc.typeArticle-
dc.identifier.doi10.1038/s41598-022-25725-x-
dc.identifier.bibliographicCitationScientific Reports, v.12, no.1-
dc.description.isOpenAccessY-
dc.identifier.wosid000945550000001-
dc.identifier.scopusid2-s2.0-85144251817-
dc.citation.number1-
dc.citation.titleScientific Reports-
dc.citation.volume12-
dc.type.docTypeArticle-
dc.publisher.location영국-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yim, Younghee photo

Yim, Younghee
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE