Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteriaopen access

Authors
Yim, YoungheeNa, Dong GyuHa, Eun JuBaek, Jung HwanSung, Jin YongKim, Ji-hoonMoon, Won-Jin
Issue Date
Jan-2020
Publisher
KOREAN SOCIETY OF RADIOLOGY
Keywords
Thyroid nodules; Thyroid cancer; Thyroid imaging reporting and data system; Ultrasonography; Size threshold; Guidelines
Citation
KOREAN JOURNAL OF RADIOLOGY, v.21, no.1, pp 108 - 116
Pages
9
Journal Title
KOREAN JOURNAL OF RADIOLOGY
Volume
21
Number
1
Start Page
108
End Page
116
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/71818
DOI
10.3348/kjr.2019.0215
ISSN
1229-6929
2005-8330
Abstract
Objective: To investigate the concordance of three international guidelines: the Korean Thyroid Association/Korean Society of Thyroid Radiology, American Thyroid Association, and American College of Radiology for thyroid nodules classified by ultrasonography (US) and the diagnostic performance of simulated size criteria for malignant biopsies. Materials and Methods: A total of 2586 thyroid nodules (>= 1 cm) were collected from two multicenter study datasets. The classifications of the thyroid nodules were based on three different guidelines according to US categories for malignancy risk, and the concordance rate between the different guidelines was calculated for the classified nodules. In addition, the diagnostic performance of criteria related to four different simulated biopsy sizes was evaluated. Results: The concordance rate of nodules classified as high- or intermediate-suspicion was high (84.1-100%), but low-suspicion or mildly-suspicious nodules exhibited relatively low concordance (63.8-83.8%) between the three guidelines. The differences in sensitivity, specificity, and accuracy between the guidelines were 0.7-19.8%, 0-40.9%, and 0.1-30.5%, respectively, when the original biopsy criteria were applied. The differences decreased to 0-5.9%, 0-10.9%, and 0.1-8.2%, respectively, when simulated, similar biopsy size criteria were applied. The unnecessary biopsy rate calculated with the original criteria (0-33.8%), decreased with the simulated biopsy size criteria (0-8.7%). Conclusion: We found a high concordance between the three guidelines for high- or intermediate-suspicion nodules, and the diagnostic performance of the biopsy criteria was approximately equivalent for each simulated size criterion. The difference in diagnostic performance between the three guidelines is mostly influenced by the various size thresholds for biopsies.
Files in This Item
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yim, Younghee photo

Yim, Younghee
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE