Ventricular tachyarrhythmia treatment and prevention by subthreshold stimulation with stretchable epicardial multichannel electrode array

Full metadata record
DC Field Value Language
dc.contributor.authorSunwoo, Sung-Hyuk-
dc.contributor.authorCha, Myung-Jin-
dc.contributor.authorHan, Sang Ihn-
dc.contributor.authorKang, Hyejeong-
dc.contributor.authorCho, Ye Seul-
dc.contributor.authorYeom, Da-Hae-
dc.contributor.authorPark, Chan Soon-
dc.contributor.authorPark, Na Kyeong-
dc.contributor.authorChoi, Seong Woo-
dc.contributor.authorKim, Sung Joon-
dc.contributor.authorCha, Gi Doo-
dc.contributor.authorJung, Dongjun-
dc.contributor.authorChoi, Suji-
dc.contributor.authorOh, Seil-
dc.contributor.authorNam, Gi-Byoung-
dc.contributor.authorHyeon, Taeghwan-
dc.contributor.authorKim, Dae-Hyeong-
dc.contributor.authorLee, Seung-Pyo-
dc.date.accessioned2024-02-16T05:30:52Z-
dc.date.available2024-02-16T05:30:52Z-
dc.date.issued2023-03-
dc.identifier.issn2375-2548-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/72058-
dc.description.abstractThe implantable cardioverter-defibrillator (ICD) is an effective method to prevent sudden cardiac death in high -risk patients. However, the transvenous lead is incompatible with large-area electrophysiological mapping and cannot accommodate selective multichannel precision stimulations. Moreover, it involves high-energy shocks, resulting in pain, myocardial damage, and recurrences of ventricular tachyarrhythmia (VTA). We present a method for VTA treatment based on subthreshold electrical stimulations using a stretchable epicardial multi-channel electrode array, which does not disturb the normal contraction or electrical propagation of the ventri-cle. In rabbit models with myocardial infarction, the infarction was detected by mapping intracardiac electrograms with the stretchable epicardial multichannel electrode array. Then, VTAs could be terminated by sequential electrical stimuli from the epicardial multichannel electrode array beginning with low-energy sub-threshold stimulations. Last, we used these subthreshold stimulations to prevent the occurrence of additional VTAs. The proposed protocol using the stretchable epicardial multichannel electrode array provides opportu-nities toward the development of innovative methods for painless ICD therapy.-
dc.language영어-
dc.language.isoENG-
dc.publisherAMER ASSOC ADVANCEMENT SCIENCE-
dc.titleVentricular tachyarrhythmia treatment and prevention by subthreshold stimulation with stretchable epicardial multichannel electrode array-
dc.typeArticle-
dc.identifier.doi10.1126/sciadv.adf6856-
dc.identifier.bibliographicCitationSCIENCE ADVANCES, v.9, no.13-
dc.description.isOpenAccessN-
dc.identifier.wosid000969620700003-
dc.identifier.scopusid2-s2.0-85151330130-
dc.citation.number13-
dc.citation.titleSCIENCE ADVANCES-
dc.citation.volume9-
dc.type.docTypeArticle-
dc.publisher.location미국-
dc.subject.keywordPlusIMPEDANCE SPECTROSCOPY-
dc.subject.keywordPlusLEAD PLACEMENT-
dc.subject.keywordPlusTACHYCARDIA-
dc.subject.keywordPlusTERMINATION-
dc.subject.keywordPlusPACEMAKER-
dc.subject.keywordPlusDEFIBRILLATORS-
dc.subject.keywordPlusPERFORATION-
dc.subject.keywordPlusREDUCTION-
dc.subject.keywordPlusTHERAPIES-
dc.subject.keywordPlusPEDOTPSS-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Biotechnology & Natural Resource > Department of Systems Biotechnology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cha, Gi Doo photo

Cha, Gi Doo
생명공학대학 (시스템생명공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE