Development of fluorometric detection for saxitoxin with its specific binding peptide
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Tae Hee | - |
dc.contributor.author | Cho, Chae Hwan | - |
dc.contributor.author | Kweon, So Yeon | - |
dc.contributor.author | Kim, Su Min | - |
dc.contributor.author | Kailasa, Suresh Kumar | - |
dc.contributor.author | Park, Jong Pil | - |
dc.contributor.author | Park, Chan Yeong | - |
dc.contributor.author | Park, Tae Jung | - |
dc.date.accessioned | 2024-03-11T05:33:07Z | - |
dc.date.available | 2024-03-11T05:33:07Z | - |
dc.date.issued | 2024-02 | - |
dc.identifier.issn | 2635-0998 | - |
dc.identifier.issn | 2635-0998 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/72747 | - |
dc.description.abstract | Saxitoxin (STX) is a representative neurotoxin among paralytic shellfish poisons and poses a serious threat to human health. When ingested, it blocks sodium permeability of excitatory membranes and causes neuromuscular paralysis and respiratory arrest, leading to death. Therefore, technology capable of detecting STX in advance is required. In this study, to develop the bioreceptor that specifically binds to STX, a phage display was introduced. For this technique, the STX hapten was synthesized by reacting the amine group of STX with the carboxyl group of ovalbumin, a carrier protein, using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide and N-hydroxysulfosuccinimide sodium salt coupling reaction. The peptides discovered through this were selected according to frequency and similarity, and the 5 '-terminal was modified with 5-carboxyfluorescein as the fluorophore. To construct a simple verification procedure for the discovered peptides, we developed a peptide-based fluorometric sensor using the graphene oxide (GO) quenching phenomenon. In this sensor, GO as a quencher can be strongly adsorbed through pi-pi interaction with a fluorophore and charge-charge interaction with STX at pH 7.4, and it showed a low detection limit of 1.5 ppb. A fluorometric sensor for marine saxitoxin was developed using its specific binding peptide based on the graphene oxide-mediated quenching phenomenon. | - |
dc.format.extent | 8 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | ROYAL SOC CHEMISTRY | - |
dc.title | Development of fluorometric detection for saxitoxin with its specific binding peptide | - |
dc.type | Article | - |
dc.identifier.doi | 10.1039/d3sd00295k | - |
dc.identifier.bibliographicCitation | SENSORS & DIAGNOSTICS, v.3, no.2, pp 301 - 308 | - |
dc.description.isOpenAccess | Y | - |
dc.identifier.wosid | 001140062000001 | - |
dc.identifier.scopusid | 2-s2.0-85182910901 | - |
dc.citation.endPage | 308 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 301 | - |
dc.citation.title | SENSORS & DIAGNOSTICS | - |
dc.citation.volume | 3 | - |
dc.type.docType | Article | - |
dc.publisher.location | 영국 | - |
dc.subject.keywordPlus | MARINE | - |
dc.subject.keywordPlus | CONSUMPTION | - |
dc.subject.keywordPlus | NEUROTOXIN | - |
dc.subject.keywordPlus | TARGETS | - |
dc.subject.keywordPlus | TOXINS | - |
dc.subject.keywordPlus | ASSAY | - |
dc.subject.keywordPlus | HPLC | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | esci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.