Estimation of Continuous Arterial Blood Pressure Waveform from Photoplethysmogram in Terms of Loss Function Focus on Blood Pressure
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Oh, Haesung | - |
dc.contributor.author | Han, Sujeong | - |
dc.contributor.author | Lee, Jaesung | - |
dc.date.accessioned | 2024-03-28T04:30:31Z | - |
dc.date.available | 2024-03-28T04:30:31Z | - |
dc.date.issued | 2024-01 | - |
dc.identifier.issn | 0747-668X | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/73048 | - |
dc.description.abstract | Blood pressure (BP) monitoring is one of the most important factors in preventing cardiovascular disease. Existing blood pressure measurement methods have limitations in that they are inappropriate for real-Time blood pressure monitoring. Recently, many studies have been conducted to estimate blood pressure using Photoplethysmogram (PPG), which has several advantages. Arterial blood pressure (ABP) reconstruction studies from PPG have attempted to overcome the limitations of existing studies. The ABP waveform can obtain the most accurate blood pressure and also contribute to the diagnosis and prevention of cardiovascular diseases. In this study, we propose a novel loss function that can be applied to a machine-learning or deep-learning model that reconstructs PPG into ABP. We confirmed the improvement in blood pressure estimation performance by applying the proposed loss function. © 2024 IEEE. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Institute of Electrical and Electronics Engineers Inc. | - |
dc.title | Estimation of Continuous Arterial Blood Pressure Waveform from Photoplethysmogram in Terms of Loss Function Focus on Blood Pressure | - |
dc.type | Article | - |
dc.identifier.doi | 10.1109/ICCE59016.2024.10444137 | - |
dc.identifier.bibliographicCitation | Digest of Technical Papers - IEEE International Conference on Consumer Electronics, v.2024 IEEE | - |
dc.description.isOpenAccess | N | - |
dc.identifier.scopusid | 2-s2.0-85187002339 | - |
dc.citation.title | Digest of Technical Papers - IEEE International Conference on Consumer Electronics | - |
dc.citation.volume | 2024 IEEE | - |
dc.type.docType | Conference paper | - |
dc.subject.keywordAuthor | Arterial Blood Pressure | - |
dc.subject.keywordAuthor | Blood Pressure | - |
dc.subject.keywordAuthor | Photoplethysmogram | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.