Numerical study on the effect of separate cannulation method on hemodynamics in an arteriovenous graft

Full metadata record
DC Field Value Language
dc.contributor.authorSung, Kun Hyuk-
dc.contributor.authorKim, Hyangkyoung-
dc.contributor.authorRyou, Hong Sun-
dc.date.available2019-03-08T13:40:27Z-
dc.date.issued2016-02-
dc.identifier.issn1738-494X-
dc.identifier.issn1976-3824-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/7338-
dc.description.abstractGenerally, the hemodialysis patient with the prosthetic arteriovenous graft (AVG) undergoes two punctures with needles on the graft in every dialysis session. As an alternative method for patients with AVGs, clinicians and nurses often return the blood filtered by a dialysis machine to an autologous vein not the graft, and that is defined as a separate cannulation method. In this study, we numerically evaluate the influence of the separate cannulation method on the hemodynamics by using clinical information of six patients. In the results, when the separate cannulation method is used, the low time-averaged wall shear stress region increases whereas the high oscillatory shear index region decreases at the venous anastomosis and proximal vein. The quantitative analysis using hemodynamic index indicates the separated cannulation method has pros and cons on the occurrence of complications in AVGs.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherKOREAN SOC MECHANICAL ENGINEERS-
dc.titleNumerical study on the effect of separate cannulation method on hemodynamics in an arteriovenous graft-
dc.typeArticle-
dc.identifier.doi10.1007/s12206-016-0151-4-
dc.identifier.bibliographicCitationJOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, v.30, no.2, pp 963 - 970-
dc.identifier.kciidART002078418-
dc.description.isOpenAccessN-
dc.identifier.wosid000372237800053-
dc.identifier.scopusid2-s2.0-84957878301-
dc.citation.endPage970-
dc.citation.number2-
dc.citation.startPage963-
dc.citation.titleJOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY-
dc.citation.volume30-
dc.type.docTypeArticle-
dc.publisher.location대한민국-
dc.subject.keywordAuthorArteriovenous graft-
dc.subject.keywordAuthorComputational fluid dynamics-
dc.subject.keywordAuthorHemodynamics-
dc.subject.keywordAuthorCannulation method-
dc.subject.keywordAuthorSecondary flows-
dc.subject.keywordPlusPULSATILE FLOW-
dc.subject.keywordPlusCAROTID BIFURCATION-
dc.subject.keywordPlusSHEAR-STRESS-
dc.subject.keywordPlusARTERY-
dc.subject.keywordPlusBLOOD-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryEngineering, Mechanical-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Mechanical Engineering > 1. Journal Articles
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE