Detailed Information

Cited 5 time in webofscience Cited 5 time in scopus
Metadata Downloads

Simultaneous determination of 3-O-acetyloleanolic acid and oleanolic acid in rat plasma using liquid chromatography coupled to tandem mass spectrometry

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Eunyoung-
dc.contributor.authorNoh, Keumhan-
dc.contributor.authorLee, Sang Joon-
dc.contributor.authorShin, Beomsoo-
dc.contributor.authorHwang, Joo Tae-
dc.contributor.authorLee, Seung Woong-
dc.contributor.authorRho, Mun-Chul-
dc.contributor.authorKang, Wonku-
dc.date.available2019-03-08T13:40:48Z-
dc.date.issued2016-01-
dc.identifier.issn0731-7085-
dc.identifier.issn1873-264X-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/7361-
dc.description.abstract3-O-Acetyloleanolic acid (OAA) is a triterpenoid compound, and exerts an apoptosis in cancer cell lines, an inhibition of both atopic and allergic contact dermatitis in murine model, and a suppression of inflammatory bone loss in mice. OAA can be converted into oleanolic acid (OA) by hydrolysis in vivo, and OA exhibits several pharmacological effects as well. A liquid chromatographic method using tandem mass spectrometry (MS/MS) was developed for the simultaneous determination of OAA and OA in rat plasma. After liquid-liquid extraction with ethylacetate, both substances were chromatographed on a reversed phase column with a mobile phase of 0.1% formic acid aqueous solution and acetonitrile (1:9, v/v). The accuracy and precision of the assay were in accordance with FDA regulations for the validation of bioanalytical methods. This analytical method was successfully applied to monitor plasma concentrations of both substances over time following an intravenous administration of OAA in rats. (c) 2015 Elsevier B.V. All rights reserved.-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisherELSEVIER SCIENCE BV-
dc.titleSimultaneous determination of 3-O-acetyloleanolic acid and oleanolic acid in rat plasma using liquid chromatography coupled to tandem mass spectrometry-
dc.typeArticle-
dc.identifier.doi10.1016/j.jpba.2015.10.030-
dc.identifier.bibliographicCitationJOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, v.118, pp 96 - 100-
dc.description.isOpenAccessN-
dc.identifier.wosid000367633800012-
dc.identifier.scopusid2-s2.0-84946415200-
dc.citation.endPage100-
dc.citation.startPage96-
dc.citation.titleJOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS-
dc.citation.volume118-
dc.type.docTypeArticle-
dc.publisher.location네델란드-
dc.subject.keywordAuthor3-O-Acetyloleanolic acid-
dc.subject.keywordAuthorOleanolic acid-
dc.subject.keywordAuthorLC-MS/MS-
dc.subject.keywordAuthorRat plasma-
dc.subject.keywordPlusMICE-
dc.subject.keywordPlusPHARMACOKINETICS-
dc.subject.keywordPlusMETABOLITES-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaPharmacology & Pharmacy-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryPharmacology & Pharmacy-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Pharmacy > School of Pharmacy > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Won Ku photo

Kang, Won Ku
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE