Effect of Poly(Lactide-Co-Glycolide) Nanoparticles on Local Retention of Fluorescent Material: An Experimental Study in Mice
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kang, Yeonah | - |
dc.contributor.author | Lee, Eugene | - |
dc.contributor.author | Lee, Joon Woo | - |
dc.contributor.author | Kim, Sung Rae | - |
dc.contributor.author | Kang, Myung Joo | - |
dc.contributor.author | Choi, Young Wook | - |
dc.contributor.author | Ahn, Joong Mo | - |
dc.contributor.author | Kang, Yusuhn | - |
dc.contributor.author | Kang, Heung Sik | - |
dc.date.available | 2019-01-22T12:38:18Z | - |
dc.date.issued | 2018-09 | - |
dc.identifier.issn | 1229-6929 | - |
dc.identifier.issn | 2005-8330 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/806 | - |
dc.description.abstract | Objective: Poly(lactide-co-glycolide) (PLGA) nanoparticles are promising materials for the development of new drugreleasing systems. The purpose of this study was to evaluate the in vivo retention time of materials loaded in nanoparticles as compared with that of the material alone by in vivo imaging in nude mice. Materials and Methods: Mice (n = 20) were injected with 0.1 mL fluorescent material 1,1'-dioctadecyl-3,3,3',3' tetramethylindotricarbocyanine iodide (DiR)-loaded PLGA nanoparticles (200 nm) into the right paraspinal muscle, and the same volume of pure DiR solution was injected into the left paraspinal muscle. Fluorescence images were obtained using an in vivo optical imaging system. Fluorescent images were taken 1 day after the injection, and seven more images were taken at 1-week intervals. Image analysis was done with ImagedJ program, and one region of interest was chosen manually, which corresponded to the highest signal-intensity area of fluorescence signal intensity. Results: After 7 weeks, 12 mice showed a right-sided dominant signal, representing the DiR loaded PLGA nanoparticles; 5 mice showed a left-side dominant signal, representing the free DiR solution; and 3 mice showed no signal at all beginning 1 day after the injection. During the 7-week period, the mean signal intensities of the free DiR solution and DiR-loaded PLGA nanoparticles diverged gradually. On day 1, the mean signal intensity of free DiR solution was significantly higher than that of DiR-loaded PLGA (p < 0.001). Finally, by week 7, DiR-loaded PLGA express significantly high signal intensity compared with free DiR solution (p = 0.031). Conclusion: The results of the current study suggested that therapeutic agents bound to PLGA nanoparticles may exhibit prolonged retention times. | - |
dc.format.extent | 7 | - |
dc.publisher | KOREAN RADIOLOGICAL SOC | - |
dc.title | Effect of Poly(Lactide-Co-Glycolide) Nanoparticles on Local Retention of Fluorescent Material: An Experimental Study in Mice | - |
dc.type | Article | - |
dc.identifier.doi | 10.3348/kjr.2018.19.5.950 | - |
dc.identifier.bibliographicCitation | KOREAN JOURNAL OF RADIOLOGY, v.19, no.5, pp 950 - 956 | - |
dc.identifier.kciid | ART002391451 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000441067700016 | - |
dc.identifier.scopusid | 2-s2.0-85051367230 | - |
dc.citation.endPage | 956 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 950 | - |
dc.citation.title | KOREAN JOURNAL OF RADIOLOGY | - |
dc.citation.volume | 19 | - |
dc.type.docType | Article | - |
dc.publisher.location | 대한민국 | - |
dc.subject.keywordAuthor | Nanoparticle | - |
dc.subject.keywordAuthor | DiR | - |
dc.subject.keywordAuthor | Local retention time | - |
dc.subject.keywordAuthor | Animal study | - |
dc.subject.keywordAuthor | In vivo imaging | - |
dc.subject.keywordAuthor | Spine intervention | - |
dc.subject.keywordPlus | LOW-BACK-PAIN | - |
dc.subject.keywordPlus | ZYGAPOPHYSEAL JOINTS | - |
dc.subject.keywordPlus | REFERRED PAIN | - |
dc.subject.keywordPlus | DORSAL RAMI | - |
dc.subject.keywordPlus | INJECTION | - |
dc.subject.keywordPlus | DELIVERY | - |
dc.subject.keywordPlus | SYNOVIUM | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.