High Accuracy Concentration Analysis of Accelerator Components in Acidic Cu Superfilling Bath

Full metadata record
DC Field Value Language
dc.contributor.authorChoe, Seunghoe-
dc.contributor.authorKim, Myung Jun-
dc.contributor.authorKim, Kwang Hwan-
dc.contributor.authorKim, Hoe Chul-
dc.contributor.authorJeon, Yongkeun-
dc.contributor.authorKim, Tae Young-
dc.contributor.authorKim, Soo-Kil-
dc.contributor.authorKim, Jae Jeong-
dc.date.available2019-03-08T15:57:08Z-
dc.date.issued2016-
dc.identifier.issn0013-4651-
dc.identifier.issn1945-7111-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/8647-
dc.description.abstractWe have devised a modified cyclic voltammetry stripping (CVS) method to measure the concentrations of bis-(sulfopropyl) disulfide (SPS) and 3-mercapto-1-propane sulfonate (MPS) in Cu plating solutions. Though MPS, a breakdown product of SPS, enhances the Cu deposition rate on flat electrodes, it is not a superfilling-capable accelerator for the damascene structure, unlike SPS. Therefore, accurate measurement of SPS in damascene Cu plating baths is important. However, enhancement of the Cu deposition rate by MPS interferes with the electrochemical signal of SPS, leading to a significant error when using the modified linear approximation technique (MLAT)-CVS analysis method. To evaluate their concentrations individually, a two-step CVS analysis was performed in which the total accelerator concentration ([SPS] + 1/2[MPS]) and conversion ratio were separately determined. All MPS species in the bath were oxidized to SPS by controlling the plating solution pH. Subsequent MLAT-CVS analysis successfully revealed the total accelerator concentration in the Cu plating solution. Individual SPS and MPS concentrations were thereby calculated using the conversion ratio evaluated from the difference in their relative accelerating abilities. This modified method enabled determination of the SPS concentration with <10% error, suggesting a reliable and high accuracy tool to predict pattern filling capabilities of plating solutions. (C) The Author(s) 2015. Published by ECS.-
dc.language영어-
dc.language.isoENG-
dc.publisherELECTROCHEMICAL SOC INC-
dc.titleHigh Accuracy Concentration Analysis of Accelerator Components in Acidic Cu Superfilling Bath-
dc.typeArticle-
dc.identifier.doi10.1149/2.0471602jes-
dc.identifier.bibliographicCitationJOURNAL OF THE ELECTROCHEMICAL SOCIETY, v.163, no.2, pp D33 - D39-
dc.description.isOpenAccessY-
dc.identifier.wosid000367324400051-
dc.identifier.scopusid2-s2.0-84949571159-
dc.citation.endPageD39-
dc.citation.number2-
dc.citation.startPageD33-
dc.citation.titleJOURNAL OF THE ELECTROCHEMICAL SOCIETY-
dc.citation.volume163-
dc.type.docTypeArticle-
dc.publisher.location미국-
dc.subject.keywordPlusCOPPER PLATING BATHS-
dc.subject.keywordPlusADVANCED INTERCONNECT METALLIZATION-
dc.subject.keywordPlusELECTROLYTIC ZINC BATH-
dc.subject.keywordPlusELECTROPLATING BATH-
dc.subject.keywordPlusORGANIC ADDITIVES-
dc.subject.keywordPlusDISULFIDE SPS-
dc.subject.keywordPlusOPEN-CIRCUIT-
dc.subject.keywordPlusELECTRODEPOSITION-
dc.subject.keywordPlusCHEMISTRY-
dc.subject.keywordPlusBEHAVIOR-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryMaterials Science, Coatings & Films-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
Appears in
Collections
College of ICT Engineering > School of Integrative Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Soo Kil photo

Kim, Soo Kil
창의ICT공과대학 (융합공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE