Membrane-Based Microwave-Mediated Electrochemical Immunoassay for the In Vitro, Highly Sensitive Detection of Osteoporosis-Related Biomarkers
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Hye Youn | - |
dc.contributor.author | Sato, Shinobu | - |
dc.contributor.author | Takenaka, Shigeori | - |
dc.contributor.author | Lee, Min-Ho | - |
dc.date.available | 2019-01-22T12:58:50Z | - |
dc.date.issued | 2018-09 | - |
dc.identifier.issn | 1424-8220 | - |
dc.identifier.issn | 1424-8220 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/882 | - |
dc.description.abstract | Highly sensitive and multiplexed in vitro detection of osteoporosis-related biochemical markers were carried out based on the membrane-based microwave-mediated electrochemical immunoassay (MMeEIA), where we can dramatically reduce the sample preparation time by shortening the incubation time of conjugation to obtain sensitive detection based on three dimensional conjugation of antibodies with target antigens in nylon membrane disk. C-terminal cross-linked telopeptide of type I collagen (CTx), Osteocalcin (OC), parathyroid hormone (PTH), and N-terminal propeptide of type I collagen (P1NP), which can be utilized to monitor the progress of osteoporosis, were quantified using their corresponding antibody immobilized in membranes. Coefficient of variations in this intra- and inter-assays were within 8.0% for all markers. When compared with data obtained from clinically used standard equipment (Roche modular E170), their coefficients of determination, R-2 values, are mostly more than 0.9. They show that the results obtained from MMeEIA are in good agreement with that from the conventional clinical instruments. | - |
dc.publisher | MDPI | - |
dc.title | Membrane-Based Microwave-Mediated Electrochemical Immunoassay for the In Vitro, Highly Sensitive Detection of Osteoporosis-Related Biomarkers | - |
dc.type | Article | - |
dc.identifier.doi | 10.3390/s18092933 | - |
dc.identifier.bibliographicCitation | SENSORS, v.18, no.9 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000446940600192 | - |
dc.identifier.scopusid | 2-s2.0-85053077302 | - |
dc.citation.number | 9 | - |
dc.citation.title | SENSORS | - |
dc.citation.volume | 18 | - |
dc.type.docType | Article | - |
dc.publisher.location | 스위스 | - |
dc.subject.keywordAuthor | membrane-based microwave-mediated electrochemical immunoassay (MMeEIA) | - |
dc.subject.keywordAuthor | bone turnover marker | - |
dc.subject.keywordAuthor | osteoporosis | - |
dc.subject.keywordAuthor | C-terminal cross-linked telopeptide of type I collagen (CTx) | - |
dc.subject.keywordAuthor | osteocalcin (OC) | - |
dc.subject.keywordAuthor | parathyroid hormone (PTH) | - |
dc.subject.keywordAuthor | N-terminal propeptide of type I collagen (P1NP) | - |
dc.subject.keywordPlus | BONE TURNOVER MARKERS | - |
dc.subject.keywordPlus | ALKALINE-PHOSPHATASE | - |
dc.subject.keywordPlus | PARATHYROID-HORMONE | - |
dc.subject.keywordPlus | SERUM-LEVELS | - |
dc.subject.keywordPlus | WOMEN | - |
dc.subject.keywordPlus | OSTEOCALCIN | - |
dc.subject.keywordPlus | DIAGNOSIS | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.