Detailed Information

Cited 2 time in webofscience Cited 3 time in scopus
Metadata Downloads

Membrane-Based Microwave-Mediated Electrochemical Immunoassay for the In Vitro, Highly Sensitive Detection of Osteoporosis-Related Biomarkers

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Hye Youn-
dc.contributor.authorSato, Shinobu-
dc.contributor.authorTakenaka, Shigeori-
dc.contributor.authorLee, Min-Ho-
dc.date.available2019-01-22T12:58:50Z-
dc.date.issued2018-09-
dc.identifier.issn1424-8220-
dc.identifier.issn1424-8220-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/882-
dc.description.abstractHighly sensitive and multiplexed in vitro detection of osteoporosis-related biochemical markers were carried out based on the membrane-based microwave-mediated electrochemical immunoassay (MMeEIA), where we can dramatically reduce the sample preparation time by shortening the incubation time of conjugation to obtain sensitive detection based on three dimensional conjugation of antibodies with target antigens in nylon membrane disk. C-terminal cross-linked telopeptide of type I collagen (CTx), Osteocalcin (OC), parathyroid hormone (PTH), and N-terminal propeptide of type I collagen (P1NP), which can be utilized to monitor the progress of osteoporosis, were quantified using their corresponding antibody immobilized in membranes. Coefficient of variations in this intra- and inter-assays were within 8.0% for all markers. When compared with data obtained from clinically used standard equipment (Roche modular E170), their coefficients of determination, R-2 values, are mostly more than 0.9. They show that the results obtained from MMeEIA are in good agreement with that from the conventional clinical instruments.-
dc.publisherMDPI-
dc.titleMembrane-Based Microwave-Mediated Electrochemical Immunoassay for the In Vitro, Highly Sensitive Detection of Osteoporosis-Related Biomarkers-
dc.typeArticle-
dc.identifier.doi10.3390/s18092933-
dc.identifier.bibliographicCitationSENSORS, v.18, no.9-
dc.description.isOpenAccessN-
dc.identifier.wosid000446940600192-
dc.identifier.scopusid2-s2.0-85053077302-
dc.citation.number9-
dc.citation.titleSENSORS-
dc.citation.volume18-
dc.type.docTypeArticle-
dc.publisher.location스위스-
dc.subject.keywordAuthormembrane-based microwave-mediated electrochemical immunoassay (MMeEIA)-
dc.subject.keywordAuthorbone turnover marker-
dc.subject.keywordAuthorosteoporosis-
dc.subject.keywordAuthorC-terminal cross-linked telopeptide of type I collagen (CTx)-
dc.subject.keywordAuthorosteocalcin (OC)-
dc.subject.keywordAuthorparathyroid hormone (PTH)-
dc.subject.keywordAuthorN-terminal propeptide of type I collagen (P1NP)-
dc.subject.keywordPlusBONE TURNOVER MARKERS-
dc.subject.keywordPlusALKALINE-PHOSPHATASE-
dc.subject.keywordPlusPARATHYROID-HORMONE-
dc.subject.keywordPlusSERUM-LEVELS-
dc.subject.keywordPlusWOMEN-
dc.subject.keywordPlusOSTEOCALCIN-
dc.subject.keywordPlusDIAGNOSIS-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of ICT Engineering > School of Integrative Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Min-Ho photo

Lee, Min-Ho
창의ICT공과대학 (융합공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE