Detailed Information

Cited 16 time in webofscience Cited 19 time in scopus
Metadata Downloads

AN IMPROVED ELECTRICAL-CONDUCTANCE SENSOR FOR VOID-FRACTION MEASUREMENT IN A HORIZONTAL PIPE

Full metadata record
DC Field Value Language
dc.contributor.authorKo, Min Seok-
dc.contributor.authorLee, Bo An-
dc.contributor.authorWon, Woo Youn-
dc.contributor.authorLee, Yeon Gun-
dc.contributor.authorJerng, Dong Wook-
dc.contributor.authorKim, Sin-
dc.date.available2019-03-08T16:01:01Z-
dc.date.issued2015-12-
dc.identifier.issn1738-5733-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/8865-
dc.description.abstractThe electrical-impedance method has been widely used for void-fraction measurement in two-phase flow due to its many favorable features. In the impedance method, the response characteristics of the electrical signal heavily depend upon flow pattern, as well as phasic volume. Thus, information on the flow pattern should be given for reliable void-fraction measurement. This study proposes an improved electrical-conductance sensor composed of a three-electrode set of adjacent and opposite electrodes. In the proposed sensor, conductance readings are directly converted into the flow pattern through a specified criterion and are consecutively used to estimate the corresponding void fraction. Since the flow pattern and the void fraction are evaluated by reading conductance measurements, complexity of data processing can be significantly reduced and real-time information provided. Before actual applications, several numerical calculations are performed to optimize electrode and insulator sizes, and optimal design is verified by static experiments. Finally, the proposed sensor is applied for air-water two-phase flow in a horizontal loop with a 40-mm inner diameter and a 5-m length, and its measurement results are compared with those of a wire-mesh sensor. Copyright (C) 2015, Published by Elsevier Korea LLC on behalf of Korean Nuclear Society.-
dc.format.extent10-
dc.language영어-
dc.language.isoENG-
dc.publisherKOREAN NUCLEAR SOC-
dc.titleAN IMPROVED ELECTRICAL-CONDUCTANCE SENSOR FOR VOID-FRACTION MEASUREMENT IN A HORIZONTAL PIPE-
dc.typeArticle-
dc.identifier.doi10.1016/j.net.2015.06.015-
dc.identifier.bibliographicCitationNUCLEAR ENGINEERING AND TECHNOLOGY, v.47, no.7, pp 804 - 813-
dc.identifier.kciidART002057818-
dc.description.isOpenAccessN-
dc.identifier.wosid000366528800002-
dc.identifier.scopusid2-s2.0-84949489324-
dc.citation.endPage813-
dc.citation.number7-
dc.citation.startPage804-
dc.citation.titleNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.citation.volume47-
dc.type.docTypeArticle-
dc.publisher.location대한민국-
dc.subject.keywordAuthorConductance Sensor-
dc.subject.keywordAuthorFlow Pattern-
dc.subject.keywordAuthorVoid Fraction-
dc.subject.keywordAuthorWire-mesh Sensor-
dc.subject.keywordPlusGAS-LIQUID FLOWS-
dc.subject.keywordPlus2-PHASE FLOW-
dc.subject.keywordPlusPATTERN IDENTIFICATION-
dc.subject.keywordPlusIMPEDANCE METHOD-
dc.subject.keywordPlusPROBE-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Energy System Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jerng, Dong Wook photo

Jerng, Dong Wook
공과대학 (에너지시스템 공학부)
Read more

Altmetrics

Total Views & Downloads