Measurement of five-degrees-of-freedom spindle error motion using multi probe error separation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Baek, Sang woo | - |
dc.contributor.author | Hwang, In-Oh | - |
dc.contributor.author | Cho, Nahm-Gyoo | - |
dc.date.accessioned | 2021-07-28T08:12:00Z | - |
dc.date.available | 2021-07-28T08:12:00Z | - |
dc.date.created | 2021-07-14 | - |
dc.date.issued | 2021-07 | - |
dc.identifier.issn | 0954-4054 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/105798 | - |
dc.description.abstract | Herein, a precision measurement method is proposed to evaluate the radial, axial, and tilt error motions of rotating devices such as precision spindles. To improve the accuracy of the estimated multiple-degree-of-freedom error motion components, form error signals in the runout signals are separated and precompensated for before the calculation of the five-degrees-of-freedom error motion components. Fourier model-based multi probe error separation (MPES) techniques, which can prevent the occurrence of harmonic distortions, are applied to separate the form error signals. A three-probe method is applied to layers on the side surface of the cylindrical artifact, and a modified two-probe method is developed and applied to the upper surface. The radial, tilt, and axial error motions are calculated using the runout signals that do not contain the separated form error signals. The measurement system uses eight capacitive probes to detect the runout signals of the cylindrical artifact mounted at the center of the rotating device. To compare the proposed method with the five-probe-based conventional measuring method, an evaluation test simulation is conducted repeatedly five times. Results indicate that the proposed MPES method calculated the uncertainty using the deviation between the computed results from the existing and novel methods; additionally, the input signal in terms of the radial, tilt (layers 1 and 2), and axial error motions are (Formula presented.), (Formula presented.), (Formula presented.), and (Formula presented.), respectively. It is confirmed that the undesirable effects of the form error signals are successfully removed and that the accuracies of the measured spindle error motion components improve. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | SAGE Publications Ltd | - |
dc.title | Measurement of five-degrees-of-freedom spindle error motion using multi probe error separation | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Cho, Nahm-Gyoo | - |
dc.identifier.doi | 10.1177/0954405421995665 | - |
dc.identifier.scopusid | 2-s2.0-85102042184 | - |
dc.identifier.wosid | 000669984200003 | - |
dc.identifier.bibliographicCitation | Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture, v.235, no.9, pp.1373 - 1383 | - |
dc.relation.isPartOf | Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture | - |
dc.citation.title | Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture | - |
dc.citation.volume | 235 | - |
dc.citation.number | 9 | - |
dc.citation.startPage | 1373 | - |
dc.citation.endPage | 1383 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Manufacturing | - |
dc.relation.journalWebOfScienceCategory | Engineering, Mechanical | - |
dc.subject.keywordPlus | Degrees of freedom (mechanics) | - |
dc.subject.keywordPlus | Probes | - |
dc.subject.keywordPlus | Separation | - |
dc.subject.keywordPlus | Capacitive probe | - |
dc.subject.keywordPlus | Evaluation test | - |
dc.subject.keywordPlus | Measurement system | - |
dc.subject.keywordPlus | Measuring method | - |
dc.subject.keywordPlus | Multiple-degree-of-freedom | - |
dc.subject.keywordPlus | Precision measurement | - |
dc.subject.keywordPlus | Spindle error motion | - |
dc.subject.keywordPlus | Undesirable effects | - |
dc.subject.keywordPlus | Errors | - |
dc.subject.keywordAuthor | 5-DOF rotational error motion | - |
dc.subject.keywordAuthor | error separation technique | - |
dc.subject.keywordAuthor | form error | - |
dc.subject.keywordAuthor | Fourier-model-based multi probe method | - |
dc.subject.keywordAuthor | harmonic distortion | - |
dc.subject.keywordAuthor | probe arrangement | - |
dc.subject.keywordAuthor | Spindle error motion | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.