PVP-stabilized PtRu nanozymes with peroxidase-like activity and its application for colorimetric and fluorometric glucose detection

Authors
Park, YosepGupta, Pramod K.Tran, Van KhueSon, Seong-eunHur, WonLee, HanbeenPark, JiyeonKim, SeongnyeonSeong, G.H.
Issue Date
Aug-2021
Publisher
Elsevier B.V.
Keywords
Alloy nanoparticles; Cascade enzyme reaction; Glucose determination; Nanozyme; Peroxidase-like activity
Citation
Colloids and Surfaces B: Biointerfaces, v.204, pp 1 - 8
Pages
8
Indexed
SCIE
SCOPUS
Journal Title
Colloids and Surfaces B: Biointerfaces
Volume
204
Start Page
1
End Page
8
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/105808
DOI
10.1016/j.colsurfb.2021.111783
ISSN
0927-7765
1873-4367
Abstract
Nanozymes have significant advantages over natural enzymes. The intrinsic peroxidase-like activity of Pt-based nanomaterials can be enhanced by alloying with other transition metals, such as Ru, that have great catalytic activity. In this study, we used polyvinylpyrrolidone (PVP) to synthesize well-dispersed and homogeneous nanostructures. PVP-stabilized Pt-Ru nanozymes (PVP/PtRu NZs) were synthesized and characterized. The PVP/PtRu NZs had an average size of 3.54 ± 0.84 nm and exhibited an intense peroxidase-like activity. The PVP/PtRu NZs were used as peroxidase mimics for colorimetric and fluorometric glucose determination by the glucose oxidase and PVP/PtRu NZs cascade reaction. In the colorimetric assay, the linearly detectable range was 0.25–3.0 mM, with an R2 and limit of detection (LOD) of 0.988 and 138 μM, respectively. In the fluorometric assay, a linear relationship was found when the glucose concentration was between 5.0 and 300 μM (R2 = 0.997), with an LOD of 1.11 μM. Compared to the colorimetric assay, the fluorometric assay had greater sensitivity and a lower detection limit for the determination of glucose. Moreover, the PVP/PtRu NZs had high storage stability over a month and great recovery values in human serum and artificial urine, with a range of 94–106 %. From these results, PVP/PtRu NZs are expected to be used as promising peroxidase mimics in various fields such as biosensing, pharmaceutical processing, and the food industry. © 2021 Elsevier B.V.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF BIONANO ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seong, Gi Hun photo

Seong, Gi Hun
ERICA 공학대학 (DEPARTMENT OF BIONANO ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE