Highly Reliable Passive RFID-Based Inductor-Capacitor Sensory System Strengthened by Solvatochromism for Fast and Wide-Range Lactate Detection
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Khan, Md Rajibur Rahaman | - |
dc.contributor.author | Khalilian, Alireza | - |
dc.contributor.author | Seo, Jungyoon | - |
dc.contributor.author | Oh, Seungtaek | - |
dc.contributor.author | Thakre, Atul | - |
dc.contributor.author | An, Tae Kyu | - |
dc.contributor.author | Lee, Hwa Sung | - |
dc.date.accessioned | 2022-10-07T09:18:36Z | - |
dc.date.available | 2022-10-07T09:18:36Z | - |
dc.date.issued | 2022-06 | - |
dc.identifier.issn | 1530-437X | - |
dc.identifier.issn | 1558-1748 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/110420 | - |
dc.description.abstract | A passive radio frequency-identification-based inductor-capacitor (LC) lactate sensory system with a specific dye-containing interdigitated capacitor (IDC) in which the sensing signal is amplified by the solvatochromic effect is proposed. When a lactate solution contacts the IDC of the LC lactate sensor, the capacitance of the IDC changes, changing the resonance frequency of the sensor. This changes the oscillation frequency of the Colpitts oscillator in the readout circuit. By analyzing the frequency changes, the concentration of the lactate solution can be measured quickly and accurately over a wide range. To our knowledge, the proposed device is the first passive, battery-free LC lactate sensor that uses solvatochromic dye-containing IDC sensing elements to detect lactate solution concentrations. Four solvatochromic dyes were tested and incorporated into a polymer as the lactate-sensitive membranes of the IDCs. The proposed LC sensor tag offers excellent sensitivity and linearity over a wide lactate concentration range of about 10 mu M to 1 M. The response and recovery times of our LC sensory system were significantly shorter than those of previously reported lactate sensors. Our results are useful for the development of reliable wearable devices capable of real-time lactate detection at a low cost. | - |
dc.format.extent | 9 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Institute of Electrical and Electronics Engineers | - |
dc.title | Highly Reliable Passive RFID-Based Inductor-Capacitor Sensory System Strengthened by Solvatochromism for Fast and Wide-Range Lactate Detection | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1109/JSEN.2022.3174210 | - |
dc.identifier.scopusid | 2-s2.0-85132528259 | - |
dc.identifier.wosid | 000811704400107 | - |
dc.identifier.bibliographicCitation | IEEE Sensors Journal, v.22, no.12, pp 12228 - 12236 | - |
dc.citation.title | IEEE Sensors Journal | - |
dc.citation.volume | 22 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | 12228 | - |
dc.citation.endPage | 12236 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordPlus | L-LACTIC ACID | - |
dc.subject.keywordPlus | BIOSENSOR | - |
dc.subject.keywordPlus | GLUCOSE | - |
dc.subject.keywordAuthor | Interdigitated capacitor | - |
dc.subject.keywordAuthor | passive LC tag | - |
dc.subject.keywordAuthor | lactate sensor | - |
dc.subject.keywordAuthor | dielectric constant | - |
dc.subject.keywordAuthor | solvatochromism | - |
dc.subject.keywordAuthor | oscillator | - |
dc.identifier.url | https://ieeexplore.ieee.org/document/9772637 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.