Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Electroanalytical biosensor based on GOx/FCA/PEG-modified SWCNT electrode for determination of glucose

Full metadata record
DC Field Value Language
dc.contributor.authorHan, Do Kyoung-
dc.contributor.authorLi, Cheng Ai-
dc.contributor.authorSong, Sung Ho-
dc.contributor.authorCho, Kun-
dc.contributor.authorChoi, Jong-Soon-
dc.contributor.authorSon, Seong Eun-
dc.contributor.authorSeong, Gi Hun-
dc.date.accessioned2023-05-03T09:36:00Z-
dc.date.available2023-05-03T09:36:00Z-
dc.date.issued2023-02-
dc.identifier.issn2093-3134-
dc.identifier.issn2093-3371-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/112597-
dc.description.abstractThis paper describes a simple electrochemical sensing platform based on single-walled carbon nanotube (SWCNT) electrodes for glucose detection. The device fabrication using O2-plasma treatment allows precision and uniformity for the construction of three SWCNT electrodes on the flexible plastic substrate. Glucose assay can be simply accomplished by introducing a glucose sample into the fabricated biosensor. The marked electrocatalytic and biocompatible properties of biosensors based on SWCNT electrodes with the incorporation of ferrocenecarboxylic acid and polyethylene glycol enable effective amperometric measurement of glucose at a low oxidation potential (0.3 V) with low interferences from coexisting species. The device shows efficient electroanalytical performances with high sensitivity (5.5 μA·mM−1·cm−2), good reproducibility (CV less than 3%), and long-term stability (over a month). A linear range of response was found from 0 to 10 mM of glucose with a fast response time of 10 s. This attractive electroanalytical device based on GOx/FCA/PEG/SWCNT electrodes offers a promising system to facilitate a new approach for diverse biosensors and electrochemical devices. © 2023, The Author(s).-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherSpringer Science and Business Media Deutschland GmbH-
dc.titleElectroanalytical biosensor based on GOx/FCA/PEG-modified SWCNT electrode for determination of glucose-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.1186/s40543-023-00371-8-
dc.identifier.scopusid2-s2.0-85147555377-
dc.identifier.wosid000928583300001-
dc.identifier.bibliographicCitationJournal of Analytical Science and Technology, v.14, no.1, pp 1 - 8-
dc.citation.titleJournal of Analytical Science and Technology-
dc.citation.volume14-
dc.citation.number1-
dc.citation.startPage1-
dc.citation.endPage8-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusWALLED CARBON NANOTUBE-
dc.subject.keywordPlusAMPEROMETRIC SENSOR-
dc.subject.keywordPlusURIC-ACID-
dc.subject.keywordPlusTRANSPARENT-
dc.subject.keywordPlusNANOPARTICLES-
dc.subject.keywordPlusFILMS-
dc.subject.keywordAuthorAmperometry-
dc.subject.keywordAuthorCarbon nanotube-
dc.subject.keywordAuthorElectrochemical biosensor-
dc.subject.keywordAuthorFerrocenecarboxylic acid-
dc.subject.keywordAuthorGlucose-
dc.subject.keywordAuthorPolyethylene glycol-
dc.identifier.urlhttps://jast-journal.springeropen.com/articles/10.1186/s40543-023-00371-8-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF BIONANO ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seong, Gi Hun photo

Seong, Gi Hun
ERICA 공학대학 (DEPARTMENT OF BIONANO ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE