Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

Full metadata record
DC Field Value Language
dc.contributor.authorKwak, Young Beom-
dc.contributor.authorYu, Jundong-
dc.contributor.authorYoo, Hye Hyun-
dc.date.accessioned2023-07-05T05:45:37Z-
dc.date.available2023-07-05T05:45:37Z-
dc.date.issued2022-12-
dc.identifier.issn2233-4203-
dc.identifier.issn2093-8950-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/113306-
dc.description.abstract: Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer sol-vent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 x 150 mm, 1.8 mu m). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisher사단법인 한국질량분석학회-
dc.titleSimultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.5478/MSL.2022.13.4.158-
dc.identifier.scopusid2-s2.0-85146389412-
dc.identifier.wosid000974913300008-
dc.identifier.bibliographicCitationMass Spectrometry Letters, v.13, no.4, pp 158 - 165-
dc.citation.titleMass Spectrometry Letters-
dc.citation.volume13-
dc.citation.number4-
dc.citation.startPage158-
dc.citation.endPage165-
dc.type.docTypeArticle-
dc.identifier.kciidART002919821-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClassesci-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaSpectroscopy-
dc.relation.journalWebOfScienceCategorySpectroscopy-
dc.subject.keywordAuthorDoping control-
dc.subject.keywordAuthorEquine plasma-
dc.subject.keywordAuthorLC-MS?MS-
dc.identifier.urlhttps://kiss.kstudy.com/Detail/Ar?key=3996886-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF PHARMACY > DEPARTMENT OF PHARMACY > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Hye Hyun photo

Yoo, Hye Hyun
COLLEGE OF PHARMACY (DEPARTMENT OF PHARMACY)
Read more

Altmetrics

Total Views & Downloads

BROWSE