적외선 열화상법을 이용한 벽체의 열관류율 산출을 위한 선행연구 분석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 송아현 | - |
dc.contributor.author | 김예은 | - |
dc.contributor.author | 신민재 | - |
dc.date.accessioned | 2023-08-01T06:32:42Z | - |
dc.date.available | 2023-08-01T06:32:42Z | - |
dc.date.issued | 2022-10 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/113632 | - |
dc.description.abstract | Quantitative evaluation of building insulation performance is one of the important tasks to improve the energy performance of a building. Among the quantitative indicators representing insulation performance, a representative indicator is the U-value. As taking the advantage of an IRT, which is simple and can measure multiple spaces, the wall U-value calculation methods using IRT are suggested in other countries. This paper aims to analyze previous studies on the calculation of U-value using IRT. It also presents infrared thermal imaging conditions to reduce the error rate. Based on this study, a follow-up study will be conducted to improve the U-value calculation equation using the IRT method. | - |
dc.format.extent | 2 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 대한건축학회 | - |
dc.title | 적외선 열화상법을 이용한 벽체의 열관류율 산출을 위한 선행연구 분석 | - |
dc.title.alternative | Analysis of the previous studies for calculation of U-value of walls using IRT | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.bibliographicCitation | 2022년 대한건축학회 추계학술발표대회논문집, v.42, no.2, pp 427 - 428 | - |
dc.citation.title | 2022년 대한건축학회 추계학술발표대회논문집 | - |
dc.citation.volume | 42 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 427 | - |
dc.citation.endPage | 428 | - |
dc.type.docType | Proceeding | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | 적외선 열화상 | - |
dc.subject.keywordAuthor | 열관류율 | - |
dc.subject.keywordAuthor | 단열성능 | - |
dc.subject.keywordAuthor | 현장측정 | - |
dc.subject.keywordAuthor | Infrared Thermography(IRT) | - |
dc.subject.keywordAuthor | U-value | - |
dc.subject.keywordAuthor | Thermal performance | - |
dc.subject.keywordAuthor | Field measureme | - |
dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE11162743 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.