In Vivo Usability Test of Vascular Intervention Robotic System Controlled by Two Types of Master Devices
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Song, Hwa-Seob | - |
dc.contributor.author | Woo, Jae-Hong | - |
dc.contributor.author | Won, Jong-Yun | - |
dc.contributor.author | Yi, Byung-Ju | - |
dc.date.accessioned | 2023-08-16T08:31:04Z | - |
dc.date.available | 2023-08-16T08:31:04Z | - |
dc.date.issued | 2021-06 | - |
dc.identifier.issn | 2076-3417 | - |
dc.identifier.issn | 2076-3417 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/114303 | - |
dc.description.abstract | Conventional vascular intervention (VI) procedures are typically performed manually un-der exposure to X-rays, whereby several problems are presented that need to be addressed owing to the patients and doctors being exposed to large amounts of radiation. In such cases, employing radiation protection units is not a long-term solution to avoid physical damage. Therefore, to over-come these issues, we propose a robotic VI system in this study. Moreover, we compare the extent of radiation exposure in the case of the conventional manual VI procedure with that in the case of the robotic procedure. The radiation exposure is then analyzed from the perspective of the doctor. Subsequently, the results of usability tests for two proposed master devices are presented in terms of the NASA task load index (NASA-TLX) and the system usability scale (SUS) score. To verify the effectiveness of the robotic VI system, animal experiments are conducted using a pig model. Among the two types of master devices tested with the proposed robotic VI system, the ergonomically designed 2-degree-of-freedom master device is found to be more effective than the joystick-type device in terms of the usability test scores. Hence, the proposed robotic VI procedure is shown to be advantageous in terms of reducing radiation exposure and improving usability. © 2021 by the authors. Licensee MDPI, Basel, Switzerland. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | MDPI | - |
dc.title | In Vivo Usability Test of Vascular Intervention Robotic System Controlled by Two Types of Master Devices | - |
dc.type | Article | - |
dc.publisher.location | 스위스 | - |
dc.identifier.doi | 10.3390/app11125453 | - |
dc.identifier.scopusid | 2-s2.0-85108419141 | - |
dc.identifier.wosid | 000665936500001 | - |
dc.identifier.bibliographicCitation | Applied Sciences-basel, v.11, no.12, pp 1 - 16 | - |
dc.citation.title | Applied Sciences-basel | - |
dc.citation.volume | 11 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 16 | - |
dc.type.docType | 정기학술지(Article(Perspective Article포함)) | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Engineering, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Materials Science, MultidisciplinaryPhysics, Applied | - |
dc.subject.keywordPlus | RADIATION-EXPOSURE | - |
dc.subject.keywordPlus | STEERABLE CATHETER | - |
dc.subject.keywordPlus | CARDIOLOGY | - |
dc.subject.keywordPlus | FEEDBACK | - |
dc.subject.keywordPlus | RADIOLOGY | - |
dc.subject.keywordPlus | SAFETY | - |
dc.subject.keywordAuthor | Animal experiment | - |
dc.subject.keywordAuthor | Master–slave system | - |
dc.subject.keywordAuthor | Medical robot | - |
dc.subject.keywordAuthor | Radiation exposure | - |
dc.subject.keywordAuthor | Usability test | - |
dc.subject.keywordAuthor | Vascular intervention robot | - |
dc.identifier.url | https://www.mdpi.com/2076-3417/11/12/5453 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.