음압격리병동부의 공간 프로그램 및 동선체계 디자인 가이드라인에 관한 연구/일반부문
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 박예랑 | - |
dc.contributor.author | 김상헌 | - |
dc.contributor.author | 안치원 | - |
dc.date.accessioned | 2023-09-04T05:44:12Z | - |
dc.date.available | 2023-09-04T05:44:12Z | - |
dc.date.issued | 2021-10 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/114965 | - |
dc.description.abstract | The outbreak of a new infection has led to an increase in demand for negative pressure isolation rooms. Although the importance of related facilities is growing due to infectious diseases such as covid-19, the guidelines for negative pressure isolation facilities are unclear. Therefore, this study aims to analyze the space of existing negative pressure isolation facilities, plan effective movements for the treatment of infectious diseases in the negative pressure isolation ward, and organize the space in the negative pressure isolation ward to present basic data for the plan of negative pressure isolation facilities. | - |
dc.format.extent | 4 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 대한건축학회 | - |
dc.title | 음압격리병동부의 공간 프로그램 및 동선체계 디자인 가이드라인에 관한 연구/일반부문 | - |
dc.title.alternative | A Study on the Design Guidelines for Spatial Program and Circulation System in the Negative Pressure Isolation Ward | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.bibliographicCitation | 2021년 대한건축학회 추계학술발표대회논문집, v.41, no.2, pp 560 - 563 | - |
dc.citation.title | 2021년 대한건축학회 추계학술발표대회논문집 | - |
dc.citation.volume | 41 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 560 | - |
dc.citation.endPage | 563 | - |
dc.type.docType | Proceeding | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | 중증호흡기 감염병 | - |
dc.subject.keywordAuthor | 공기감염격리병동 | - |
dc.subject.keywordAuthor | 음압 | - |
dc.subject.keywordAuthor | Severe Respiratory Infectious Disease | - |
dc.subject.keywordAuthor | Airborne Infection Isolation Unit | - |
dc.subject.keywordAuthor | Negative Pressure | - |
dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE11025042 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.