Electrical resistance-based monitoring of CFRP thickness during vacuum assisted resin infusion
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jeong, Woo Nam | - |
dc.contributor.author | Um, Moon-Kwang | - |
dc.contributor.author | Kim, Wie-Dae | - |
dc.contributor.author | Roh, Hyung Doh | - |
dc.date.accessioned | 2023-11-14T01:36:40Z | - |
dc.date.available | 2023-11-14T01:36:40Z | - |
dc.date.issued | 2023-09 | - |
dc.identifier.issn | 2631-6331 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/115513 | - |
dc.description.abstract | During vacuum-assisted resin infusion (VARI), the thickness of the fabric manufactured into carbon fiber (CF)-reinforced plastic was monitored using electrical resistance, which was correlated with the mechanical and electrical status of the CF with respect to resin infiltration. Furthermore, the electrical network within CF varied in terms of its volume and number of electrical contacts. These phenomena were monitored by installing a Cu tape on the mold. Thus, an in-situ qualitative monitoring system for composite manufacturing was developed utilizing the electrical resistance variations in the fabric. The proposed thickness-monitoring system for VARI can potentially minimize the cost, time, and labor in composite industries. | - |
dc.format.extent | 9 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | IoP Institute of Physics | - |
dc.title | Electrical resistance-based monitoring of CFRP thickness during vacuum assisted resin infusion | - |
dc.type | Article | - |
dc.publisher.location | 영국 | - |
dc.identifier.doi | 10.1088/2631-6331/acf753 | - |
dc.identifier.scopusid | 2-s2.0-85173244498 | - |
dc.identifier.wosid | 001065945900001 | - |
dc.identifier.bibliographicCitation | Functional Composites and Structures, v.5, no.3, pp 1 - 9 | - |
dc.citation.title | Functional Composites and Structures | - |
dc.citation.volume | 5 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 9 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | esci | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Composites | - |
dc.subject.keywordPlus | COMPOSITES | - |
dc.subject.keywordPlus | CARBON | - |
dc.subject.keywordAuthor | manufacturing monitoring | - |
dc.subject.keywordAuthor | resin infusion | - |
dc.subject.keywordAuthor | vacuum infusion | - |
dc.identifier.url | https://iopscience.iop.org/article/10.1088/2631-6331/acf753 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.